Compaq PROLIANT ML350 Maintenance And Service Manual page 71

Generation 3 server
Hide thumbs Also See for PROLIANT ML350:
Table of Contents

Advertisement

Connectors, Switches, and LEDs
Table 4-6: System Board LEDs
Item
5
6
7
8
9
10
11
12
13
14
15
4-12
COMPAQ CONFIDENTIAL Codename: Steel Dragon Part Number: 278704-002 Last Saved On: 12/18/02 9:49 AM
continued
Description
I/O fan status
Processor 2 status
Processor 2 thermal
PPM 2 status
PCI-X bus 2 speed
PCI-X bus 2 mode
Temperature threshold
PCI-X bus 5 speed
PCI-X bus 5 mode
CPU fan status
DIMM status (DIMM slots 1
through 4)
Compaq ProLiant ML350 Generation 3 Server Maintenance and Service Guide
Status
Off = Fan functioning
Amber = Fan is not installed or has failed
Off = Processor 2 functioning
Amber = Processor 2 failed
Off = Normal
Amber = Thermal trip detected for processor 2.
Refer to the Compaq ProLiant ML350 Generation 3
Server Setup and Installation Guide for the
appropriate instructions.
Off = PPM 2 functioning
Amber = PPM 2 failed
Off = PCI 33 MHz/PCI-X 66 MHz operating mode
On = PCI 66 MHz/PCI-X 100 MHz operating mode
Off = PCI-X mode is inactive
On = PCI-X mode is active
Off = Normal
Amber = Temperature threshold exceeded
Off = PCI 33 MHz/PCI-X 66 MHz operating mode
On = PCI 66 MHz/PCI-X 100 MHz operating mode
Off = PCI-X mode is inactive
On = PCI-X mode is active
Off = Fan functioning
Amber = Fan is not installed or has failed
Off = DIMM functioning
Amber = DIMM failed

Advertisement

Table of Contents
loading

Table of Contents