52
Maintenance Section
Aftercooler Core - Clean/Test
Aftercooler Core - Clean/Test
1. Remove the core. Refer to the OEM information
for the correct procedure.
2. Turn the aftercooler core upside-down in order to
remove debris.
Personal injury can result from air pressure.
Personal injury can result without following prop-
er procedure. When using pressure air, wear a pro-
tective face shield and protective clothing.
Maximum air pressure at the nozzle must be less
than 205 kPa (30 psi) for cleaning purposes.
3. Pressurized air is the preferred method for
removing loose debris. Direct the air in the
opposite direction of the fan's air flow. Hold the
nozzle approximately 6 mm (.25 inch) away from
the fins. Slowly move the air nozzle in a direction
that is parallel with the tubes. This will remove
debris that is between the tubes.
4. Pressurized water may also be used for cleaning.
The maximum water pressure for cleaning
purposes must be less than 275 kPa (40 psi). Use
pressurized water in order to soften mud. Clean
the core from both sides.
NOTICE
Do not use a high concentration of caustic cleaner to
clean the core. A high concentration of caustic cleaner
can attack the internal metals of the core and cause
leakage. Only use the recommended concentration of
cleaner.
5. Back flush the core with a suitable cleaner.
6. Steam clean the core in order to remove any
residue. Flush the fins of the aftercooler core.
Remove any other trapped debris.
7. Wash the core with hot, soapy water. Rinse the
core thoroughly with clean water.
i02322260
Personal injury can result from air pressure.
Personal injury can result without following prop-
er procedure. When using pressure air, wear a pro-
tective face shield and protective clothing.
Maximum air pressure at the nozzle must be less
than 205 kPa (30 psi) for cleaning purposes.
8. Dry the core with compressed air. Direct the air in
the reverse direction of the normal flow.
9. Inspect the core in order to ensure cleanliness.
Pressure test the core. If necessary, repair the
core.
10. Install the core. Refer to the OEM information for
the correct procedure.
11. After cleaning, start the engine and accelerate
the engine to high idle rpm. This will help in the
removal of debris and drying of the core. Stop the
engine. Use a light bulb behind the core in order
to inspect the core for cleanliness. Repeat the
cleaning, if necessary.
Aftercooler Core - Inspect
Note: Adjust the frequency of cleaning according to
the effects of the operating environment.
Inspect the aftercooler for these items: damaged fins,
corrosion, dirt, grease, insects, leaves, oil, and other
debris. Clean the aftercooler, if necessary.
For air-to-air aftercoolers, use the same methods that
are used for cleaning radiators.
Personal injury can result from air pressure.
Personal injury can result without following prop-
er procedure. When using pressure air, wear a pro-
tective face shield and protective clothing.
Maximum air pressure at the nozzle must be less
than 205 kPa (30 psi) for cleaning purposes.
SEBU7833-03
i02322295

Advertisement

Table of Contents
loading

This manual is also suitable for:

1104

Table of Contents