Parameterization; Principle Of Operation Of The Configuration - Siemens LOHER DYNAVERT I 6SE03 Installation Instructions Manual

Table of Contents

Advertisement

Operation

8.7 Parameterization

8.7
Parameterization
8.7.1

Principle of operation of the configuration

NOTICE
Incorrect parameterization
The converter and other connected components can be damaged or destroyed if the
parameterization is incorrect.
Only qualified personnel may change parameters; the instructions in the Operating Manual
and the technical data of the converter and connected components must be carefully
observed.
Parameterization is based on the principle - Input → Processing → Output. Many functions in
plain text are available in the bit pool for the input. You always have the selection from the
bit pool when you are in the menu of a processing function, for example when changing the
function P-ContrlRelease:Local you always have \X2:8\X2:9... for selection.
Processing functions for the output are available, for example P-Digital outputs:Relays 1-4,
LED 1-2 or P-Analog outputs.
For processing, several functions are available, e.g. P-MESSAGE GEN MESS or P-PARAMETER
SWITCH.
The following graphic clarifies this processing method:
112
Installation and Operating Instructions for LOHER DYNAVERT I Series 7
Operating Instructions, 10/2022, 4BS0745-002