Tone Break - Minelab X-TERRA PRO Instruction Manual

Hide thumbs Also See for X-TERRA PRO:
Table of Contents

Advertisement

Tone Break (Advanced Setting)
This Advanced Setting allows you to manually
control the point at which ferrous tones
occur� A use‑case example of this is coke, an
undesirable non‑ferrous 'pest' target that
typically has a Target ID of 1 or 2, though it can
go as high as 4�
By moving the ferrous tone break point up to 4 (segment 6
on the Discrimination Scale), coke is moved into the ferrous
range and will now give a ferrous response� Note however
that some low conductive targets will now give the same
response as a 'bad' ferrous target�
By default, Target IDs –19 to –4 are set as ferrous for Park
and Field Modes, and –19 to 0 are set as ferrous for Beach
Mode�
Tone Break adjustment is local; only the current Search
Mode Profile is affected by changes to this Advanced
Setting�
Tone Break is not available when Target Tone is set
to 1 Tone�
CONTENTS
ADJUST TONE BREAK
Before adjusting Tone Break, select your preferred
Target Tones setting
This is because changes to Tone Break only apply
to the active Target Tone setting�
X‑TERRA PRO allows the ferrous break point to be adjusted�
1. Navigate to the Accept/Reject setting�
2. Long‑press (2 seconds) the Settings button to select
the Tone Break Advanced Setting�
(2 Seconds)
3. 't1' will appear on the Frequency Display� The
Target ID Number will show the current value of the
ferrous tone break point, (e�g� 0), and the corresponding
Discrimination Segment will flash slowly�
4. Use the Minus (–) and Plus (+) buttons to navigate to the
Discrimination Segment you wish to use as the ferrous
tone break point�
31
(page
29)�

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents