ECO/GEAR Function
NOTE: This function is only available under COOL mode.
Press ECO/GEAR button to enter the energy
efficient mode in a sequence of following:
ECO -->GEAR(75%) -->GEAR(50%) --> Previous setting
mode -->ECO......
ECO operation:
Under cooling mode, press this button, the remote
controller will adjust the temperature automatically to
24
O
C, fan speed of Auto to save energy(but only if the
set temperature is less than 24
is above 24
C , press the ECO button, the fan speed
O
will change to Auto, the set temperature will remain
unchanged.
NOTE:
• Pressing the ON/OFF button, modifying the mode or
adjusting the set temperature to less than 24OC will
stop ECO operation.
• Under ECO operation, the set temperature should be
24OC or higher. it may result in insufficient cooling.
If you feel uncomfortable, just press the ECO button
again to stop it.
GEAR operation:
• Press this button to enter the energy efficient mode in
a sequence of following:
• This function is only available under COOL mode.
• Under GEAR operation, the display on the remote
controller will alternate between electrical energy
consumption and set temperature.
TEMP Button
Press and hold
and
buttons together for 3 seconds
will alternate the temperature display between the
O
F scale.
FP Function
When the air conditioner operates under heating mode
with the set temperature of 16
button twice in two seconds will activate 8
heating. The indoor unit display shows "FP".
Page 38
O
C). If the set temperature
O
C &
C(60
F), pressing
O
O
O
C(46
O
F)
Active Clean Function( )
• This function is used to clean the air conditioner
evaporator to prevent frosting.
• When this function is turned on, the indoor unit
display window appears "CL", after 20 to 45 minutes,
the unit will turn off automatic
Silence Function
Hold down Fan speed button( ) for 2 seconds to activate/
cancel Silent mode.
Boost Function(
)
The Boost function makes the unit work extra hard to
reach your present temperature in the shortest amount of
time possible.
Swing Button
• Press the Swing button to start or stop the horizontal
louver auto swing feature. If continue to press the
Swing button, five different airflow directions can be
set. The louver can be move at a certain range each
time you press the button.
• Hold down the Swing button for 2 seconds will start
or stop the vertical louver auto swing feature.
NOTE:
• When the unit is off, press and hold Mode and Swing
buttons together for one second, the louver will open
for a certain angle, which makes it very convenient for
cleaning.
• Press and hold Mode and Swing buttons together
for one second to reset the louver.