Help Continued - Victory HS Installation And Operating Instructions Manual

Warming cabinets
Table of Contents

Advertisement

User Manual for HS and HIS Warming Cabinets

HELP CONTINUED

Product load burning
or boiling
Product load becoming
soggy
Cabinet is noisy
Door won't close
Controller Alarm &
Error
24
Product load is too close to heating
element
Controller setpoint is too high
Too much humidity or moisture inside
cabinet
Product load held too long time.
Part(s) loose
Cabinet is not level
Hinge(s) may need slight adjustment
----
Rearrange product load so that it is not too close
to heating element(s).
Adjust controller setpoint to a lower setting.
Examples of holding times and temperatures are
within the operator's manual.
Adjust or close internal venting/damper knob to
control moisture. Normally the internal venting/
damper should be open for products such as
breaded meats, fish, etc
Hold product load inside cabinet per
recommended time. Examples of holding times
and temperatures are on page 11.
Locate and tighten loose part(s)
Level cabinet by adjusting legs or shimming caster
Apply shim(s) to hinge until door seals properly
Refer to either pages 15 or 19 of manual for alarm
codes. If problem( s) persist, contact the factory
for further assistance