User Manual for HS and HIS Warming Cabinets

HELP

PROBLEM
Cabinet not operating
Cabinet not holding
temperature
Cabinet is overheating. Defective high limit/heater safety switch
Rev. 01/23
POSSIBLE CAUSE
Fuse blown or circuit breaker tripped
Power cord unplugged
Improper voltage supplied to cabinet
(voltage does not match Data-Plate).
Main power switch and/or controller
turned off
Defective high limit/heater safety switch
Cabinet not pre-heated before use
Prolonged door opening of door ajar
Door gasket not sealing properly
Controller setpoint is too low
Improper voltage supplied to cabinet
(voltage match Data-Plate )
Product load held too long
Blower motor not operating or air duct is
air duct is restricted,
Heater elements not operating
Defective blower motor
REMEDY
Replace fuse or reset circuit breaker
Plug in power cord to designated receptacle.
Cabinet cannot share same outlet with other
equipment.
Correct supply voltage (remove extension cords or
other equipment on circuit, etc)
Turn on main power switch and/or controller.
Internal high limit/heater safety may be defective.
Contact the factory or an authorized service
provider for further assistance if all else has
been checked above and the cabinet is still not
operating.
Turn cabinet on one (1) hour before use
Make sure door is closed when not in use. Avoid
prolonged door openings.
Check door gasket condition Adjust door or
replace gasket.
Adjust controller setpoint to a higher temperature
Correct supply voltage (remove extension cords or
does not) other equipment on circuit, etc).
Hold product load inside cabinet per
recommended temperature. Examples of holding
times and temperatures are on page 11.
Check blower motor and air duct for proper air
flow. Try to carefully locate and remove the cause
of air restriction. If further assistance is restricted
required, contact the factory or authorized service
provider for further assistance.
Carefully check heater elements for proper
operation .If heating element(s) are not working
properly, contact the factory or an authorized
service provider for further assistance.
If controller setpoint is adjusted to a lower setting
and the internal cabinet temperature exceeds
+200' F, turn off cabinet and contact the factory
or an authorized service provider for further
assistance
Check blower motor operation. If blower motor
is not operating, contact the factory or an
authorized service provider.