32
Installing a board
Fig. 29: Installing a board (1)
•
Press on the clip (1) in the direction of the arrow and unhook it (2).
•
Pull off the clip (2).
•
Remove the rear slot cover plate from the slot (2).
C
Do not dispose of the slot cover. For cooling, protection against fire and in order to comply
with EMC regulations, you must refit the cover plate if you remove the board.
•
Take the new board out of its packaging.
•
Make the required settings for the board.
Fig. 30: Installing a board (2)
•
Push the board up to its slot (1) as far as the stop.
•
Press the board into the slot so that it engages.
•
Put the clip on. Make sure that the pin (a) is inserted into the screw hole.
•
Press the clip in the direction of the arrow (2). Make sure that the clip engages when
released.
•
If necessary, connect the cables.
CELSIUS M450/440
TD00-400.841.40.02.02
01.08
Page 32 of 52
CS SD SP/CO
Boards
4.2
Siemens
Medical Solutions