4)
Hold the focus at the near end and by measuring with a tester check that the conduction between check points is in the following
state.
Step (No.)
1
2
3
4
5
6
5)
If the adjustment is NG in steps 3) and 4), adjust by moving right and left the position of the focus brush and perform the adjustment
again starting with step 1).
6)
After finishing the adjustment, apply the adhesive bond (B-10) to the head of screw.
SAL55200-2 (DT 4-5.6/55-200 SAM) (DT 55-200mm F4-5.6 SAM)
Check Point
Check Item (Conductive/Non-conductive)
7 and 6
7 and 5
7 and 4
7 and 3
7 and 2
7 and 1
Table 4-7-2
Non-conductive
Non-conductive
Conductive
Conductive
Non-conductive
Conductive
4-17
4-1-2. Adjustment Flow Chart