3. Modes (persistent)
Auto: The air cleaner will run a minimum
of 30 minutes every hour The air cleaner
will monitor the amount of time your
heating and cooling system runs; if 30
minutes is not reached the air cleaner
will automatically turn on This will
maximize the amount of air cleaning
while minimizing energy consumption
Continuous: This option will provide
the maximum amount of air cleaning
available The air cleaner will be active
for 24 hours a day, seven days a week.
Off: The air cleaner will not run the fan
for the sole purpose of air cleaning
NOTE: If air cleaning is installed, air
cleaning will still occur during normal fan
operation during heating, cooling or other
indoor air quality events
12
Air Cleaning
3 Hrs
24 Hrs
3
Mode
Mode
Auto
3
Continuous
Off
HUMIDIFIER CONTROL (S86N MUPR ONLY, IF INSTALLED)
The thermostat can be
configured, through the
Installer set-up, to control
a humidifier and operate it
in one of two modes, either
1
Automatic or Manual The
thermostat will allow you
to set a range of humidity
based on an outdoor
temperature reading
(Automatic) or set and hold
a value based on a single
set point (Manual)
1. Select Humidifier from
the Main Menu
2
2. From this screen you
can select humidity level
adjustment or turning the
control on or off
3. To determine which mode
the thermostat is set to,
see 3a and 3b at right
Main Menu
Humidifier
Schedule
Hum Setting 4
On
Heat Blast
Humidifier
Dehumidifier
Ventilation
Indoor RH 30%
Humidifier
Humidifier
Hum Setting
-
Setting
55%
Off
On
Indoor RH 30%
Indoor RH 30%
3a
Automatic
Mode
3b
Manual
Mode