Test; Loopbk; Table 3-1. Normal Mode Operation - ADTRAN 1200261L1 User Manual

Atlas quad ussi module
Table of Contents

Advertisement

Chapter 3. Operation

TEST

>
» Loopbk
3-8
Conditions Causing Port Control Signal Deactivation
Signal
RTS
V.54 Loopback
511 Test On
Self-test Active
Network Test Active
No DS0 Mapped
Network Alarm
— = Do not care
Activates specific data ports testing. It also controls the activation of loop-
backs and the initiation of data test patterns. Test results display on the
ATLAS_800 front panel.
Executing port tests disrupts normal data flow in the test port.
Write security: 4; Read security: 5
Controls the activation and deactivation of loopbacks.
No Loopback
The loop is deactivated.
Local Loopback
The USSI port activates both a local loopback (back to-
ward the DTE) and a port loopback when invoked.
Remote Loopback
The remote loopback causes a V.54 loopback code to be
sent to the far end. If the device at the far end supports
V.54, the device activates a loopback on detection of the
V.54 code.
ATLAS Quad USSI Module User Manual

Table 3-1. Normal Mode Operation

CTS
DCD
Follows
Off
Off
Off
Off
Off
Off
Off
Off
Off
DSR
Off
Off
Off
Off
Off