Liner Installation And Trimming Instructions - Lincoln Electric Magnum PRO Curve HDE 350 Operator's Manual

Fcaw hyperfill ready paks.
Hide thumbs Also See for Magnum PRO Curve HDE 350:
Table of Contents

Advertisement

®
MAGNUM PRO
CURVE HDE FCAW HYPERFILL

LINER INSTALLATION AND TRIMMING INSTRUCTIONS

Installation of (KP44 and KP44N series liners)
a. Lay the gun and cable straight
b. Make sure that the set screw in the connector end is
backed out so as not to damage liner or liner bushing.
Remove and save the gas nozzle, nozzle insulator, and
gas diffuser from the end of the gun tube assembly.
c. Insert a new untrimmed liner into the connector end of
the cable. Be sure the liner bushing is sten-ciled
appropriately for the wire size being used.
d. NOTE: For liner KP44N
Before fully seating the liner bushing, it will be nec-
essary to trim the liner's inner tube
bushing using a sharp blade. After trimming, remove
any burrs from inner tube and insure that the opening
is fully open.
For all K466 connector kits tighten the set screw in the
cable connector.
e. Be sure the cable is straight and then trim the
liner to the .56" length (a gauge is included on
the wrench provided with the connection kit for
gauging the cut-off length on 350 and 450 amp
gun tubes). Remove any burrs from the end of
the liner.
f. Screw the gas diffuser onto the end of the gun tube
and tighten with the wrench provided. Use appro-
priate size wrench for 350 and 450 models.
g. Replace the nozzle insulator and gas nozzle.
the liner