Installation

Mounting

The dispense valves have multiple mounting hole
configurations (see Dimensions, page 20), which make
them ideal for use with robotic equipment or multiple
manifold high production operations.
1. Inspect dispense valve for shipping damage. If there
is damage, notify shipping carrier immediately.
2. Install compatible accessories. For a list of
accessories and installation instructions, see
Accessories, page 19.
NOTE: Follow Pressure Relief Procedure, page 9,
before changing outlet housing.
3. Securely attach the dispense valve to its mounting
fixture using socket head cap screws; see
Dimensions, page 20.
4. Connect air lines to the dispense valve:
Only use air fittings that are rated at a temperature
equal to or higher than the operating temperature of
the fluid dispensing system. Lower rated air fittings
could melt and cause damage to the dispense valve.
a. See Technical Specifications, page 21, for
maximum operating air pressure.
b. Connect air line to air/open air inlet in air section
(B). See F
. 2, page 6.
IG
c. Connect air line to air/close air inlet in air
section (B). See F
5. Connect fluid line to npt fluid inlet (J and K) in valve
body. For circulation systems, remove plug from
other inlet (F and G) and connect fluid return line.
See Technical Specifications, page 21, for
maximum operating fluid pressure.
8
NOTICE
. 2, page 6.
IG
6. Check each fitting to avoid pressure leakage from
the dispense valve.