Low Image Density; Foggy Background; High Image Density - Minolta Di450 Service Manual

Hide thumbs Also See for Di450:
Table of Contents

Advertisement

(3)

Low image density

Section
Step
1
Image Transfer Corona is dirty.
2
Wiring between HV and Image
Transfer Corona is connected.
3
Developing bias contact is
dirty or deformed.
Engine
4
PH lens is dirty.
5
Wiring between HV and devel-
oping bias is connected.
6
ATDC Sensor gain value is
correct.
1
Shading position is correct.
IR
(4)

Foggy background

Section
Step
1
Extraneous light entered
copier.
1
Cleaning Blade is dirty with
foreign matter and paper dust.
2
PC Drum is dirty with foreign
matter.
Engine
3
Sleeve/Magnet Roller is dirty.
4
Developing bias contact is
dirty or deformed.
5
Main Erase Lamp is dirty.
IR
1
Mirrors and lens are dirty.
(5)

High image density

Section
Step
1
Image Transfer Corona is dirty.
2
Wiring between HV and Image
Transfer Corona is connected.
3
Developing bias contact is
Engine
dirty or deformed.
4
Wiring between HV and devel-
oping bias is connected.
5
ATDC Sensor gain value is
correct.
1
Shading position is correct.
IR
Check
Result
Check
Result
Check
Result
T-74
Action
YES Clean or change.
NO
Connect.
YES Clean or change.
YES Clean.
NO
Connect.
NO
Re-input.
NO
Correct IR shading position.
(See ADJUSTMENT.)
Action
YES Protect copier from extrane-
ous light.
YES Clean or change.
YES Clean or change.
YES Clean.
YES Clean or change.
YES Clean.
YES Clean.
Action
YES Clean or change.
NO
Connect.
YES Clean or change.
NO
Connect.
NO
Re-input.
NO
Correct IR shading position.
(See ADJUSTMENT.)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Di550

Table of Contents