6.1.8 Rohs; Other Approvals; Emc And Environmental Type Tests - Siemens RUGGEDCOM RS416 Installation Manual

Hide thumbs Also See for RUGGEDCOM RS416:
Table of Contents

Advertisement

Certification
6.1.8 RoHS
6.1.8
RoHS
This device is declared by Siemens AG to meet the requirements of the following
RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain
hazardous substances in electrical and electronic equipment:
A copy of the Material Declaration is available online at
support.industry.siemens.com/cs/ww/en/view/109738831.
6.1.9

Other Approvals

This device meets the requirements of the following additional standards:
6.2

EMC and Environmental Type Tests

The RUGGEDCOM RS416 has passed the following EMC and environmental tests.
IEC 61850-3 Type Tests
61000-4-2
61000-4-3
61000-4-4
40
China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic
Information Products
IEEE 1613
IEEE Standard Environmental and Testing Requirements for Communications
Networking Devices in Electric Power Substations
IEC 61850-3
Communication Networks and Systems for Power Utility Automation - Part 3:
General Requirements
IEC 61000-6-2
Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity
for Industrial Environments
Test
IEC
ESD
IEC
Radiated RFI
IEC
Burst (Fast Transient)
Description
Enclosure
Contact
Enclosure Air
Enclosure
ports
Signal ports
DC Power
ports
AC Power
ports
https://
Test Levels
± 8 kV
± 15 kV
20 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
RUGGEDCOM RS416
Installation Manual, 11/2020, C79000-G8976-1018-09
Severity
Levels
4
4
a
Note
a
Note
4
4

Advertisement

Table of Contents
loading