Store the Equipment

Always relieve the pressure and flush the equipment
before storing the equipment for any length of time.
1. Follow Pressure Relief Procedure, page 22.
2. Follow Flush the Equipment, page 28.
NOTICE
Store the equipment at 32°F (0°C) or higher.
Exposure to extreme low temperatures may result in
damage to plastic parts.

Clean the Wetted Section

Routinely clean the wetted section. Determine whether
or not to disassemble equipment for cleaning.
To clean the equipment without disassembling
parts, follow Clean In-Place (CIP), page 29.
To clean the equipment by disassembling parts,
follow Clean Out-of-Place (COP), page 29.
Clean in accordance with applicable sanitary standard
codes and local regulations.
Clean In-Place (CIP)
NOTICE
To avoid equipment damage, only use cleaning
fluids that are compatible with materials of the
wetted section. To avoid damage to stainless steel
parts, do not use chlorinated cleaning fluids. Do not
exceed the maximum fluid temperature for the
materials of the wetted section. See Fluid
Temperature Range, page 49.
1. Follow Pressure Relief Procedure, page 22.
2. Flush the equipment with a compatible sanitizing
solution. Follow Flush the Equipment, page 28.
3. Circulate the compatible sanitizing solution through
the equipment. Slowly cycle the equipment as the
compatible sanitizing solution is circulated.
3A9286C
NOTE: Thoroughly circulate the compatible
sanitizing solution through the equipment and the
system prior to use.
NOTICE
To avoid equipment damage, do not exceed a fluid
inlet pressure of 15 psi (103 kPa, 1 bar) when cycling
the equipment.
4. Follow Pressure Relief Procedure, page 22.
Clean Out-of-Place (COP)
1. Follow Pressure Relief Procedure, page 22.
2. Flush the equipment with a compatible sanitizing
solution. Follow Flush the Equipment, page 28.
3. Disassemble parts as needed. See Repair, starting
on page 32.
4. Inspect parts for wear or damage. Replace as
needed.
5. Using a brush or other COP methods, wash all
wetted parts with a compatible sanitizing solution
at the recommended temperature and
concentration of the manufacturer.
6. Rinse the parts again with water and allow parts to
completely dry.
7. Inspect the parts and re-clean any soiled parts.
8. Immerse all wetted parts in an approved sanitizer
before assembly. Leave the parts in the sanitizer,
and only remove the parts one by one as needed
for assembly.
9. Reassemble the equipment as needed. See
Repair, starting on page 32.
10. Flush the equipment with a compatible sanitizing
solution. Follow Flush the Equipment, page 28.
11. Circulate the compatible sanitizing solution through
the equipment. Slowly cycle the equipment as the
compatible sanitizing solution is circulated.
NOTE: Thoroughly circulate the compatible
sanitizing solution through the equipment and the
system prior to use.
NOTICE
To avoid equipment damage, do not exceed a fluid
inlet pressure of 15 psi (103 kPa, 1 bar) when cycling
the equipment.
12. Follow Pressure Relief Procedure, page 22.
Maintenance
29