Inspection/Maintenance
Fig. 69
WARNING: Risk of burning. The heat exchanger baffles
can still be very hot even after the appliance has not
been used for some time.
▶ Cool the heat exchanger baffles with a damp cloth.
42
6 720 611 626-82.1R
▶ Remove the top baffle.
▶ Remove the bottom baffle using the extractor.
▶ Clean both baffles as required.
Fig. 70
The heat exchanger can be inspected with the aid of a
torch and a mirror.
Fig. 71
6 720 611 626-81.1R
6 720 811 922 (2014/07)