Safety Precautions - Worcester GREENSTAR 24 Installation, Commissioning And Servicing Instructions

Wall hung rsf gas fired condensing combination boiler
Table of Contents

Advertisement

Key to symbols and safety instructions
1.2

SAFETY PRECAUTIONS

IF YOU SMELL GAS:
A gas leak could potentially cause an explosion.
If you smell gas, observe the following rules.
▶ Prevent flames or sparks:
– Do not smoke, use a lighter or strike matches.
– Do not operate any electrical switches or unplug any equipment.
– Do not use the telephone or ring doorbells.
▶ Turn off the gas at the meter.
▶ Open windows and doors.
▶ Leave the building and warn your neighbours.
▶ Prevent anyone from entering the building.
▶ Stay well away from the building: call the National Gas Emergency
Service on 0800 111 999.
BOILER OPERATION:
This boiler must only be operated by a responsible adult who has
been instructed in, understands, and is aware of the boiler's
operating conditions and effects.
ensure that customers are provided with the correct equipment for their
needs, that it is installed, commissioned and serviced in accordance
with the manufacturer's instructions by competent persons and that it
meets the requirements of the appropriate Building Regulations. The
Benchmark Checklist can be used to demonstrate compliance with
Building Regulations and should be provided to the customer for future
reference.
The guarantee of this product is dependant on the Benchmark checklist
being completed and the actions undertaken.
Installers are required to carry out installation, commissioning and
servicing work in accordance with the Benchmark Code of Practice
which is available from the Heating and Hotwater Industry Council who
manage and promote the scheme.
Visit centralheating.co.uk for more information.
HEALTH AND SAFETY
The appliance contains no asbestos and no substances have been used
in the construction process that contravene the COSHH Regulations
(Control of Substances Hazardous to Health Regulations 1988).
COMBUSTION AND CORROSIVE MATERIALS
Do not store or use any combustible materials (paper, thinners, paints
etc.) inside or within the vicinity of the appliance.
Chemically aggressive substances can corrode the appliance and
invalidate any guarantee.
FITTING AND MODIFICATIONS
Fitting the appliance and any controls to the appliance may only be
carried out by a competent engineer in accordance with the current Gas
Safety (Installation and Use) Regulations.
Flue systems must not be modified in any way other than as described in
the fitting instructions. Any misuse or unauthorised modifications to the
appliance, flue or associated components and systems could invalidate
the guarantee. The manufacturer accepts no liability arising from any
such actions, excluding statutory rights.
SERVICING
Advise the user to have the system serviced annually by a competent,
qualified Gas Safe registered engineer. Approved spares must be used
to help maintain the economy, safety and reliability of the appliance.
4
Benchmark places
responsibilities on both
manufacturers and
installers. The purpose is to
IMPORTANT
The service engineer must complete the Service Record on the
Benchmark Checklist after each service.
INSTALLATION REGULATIONS
Current Gas Safety (Installation & Use) Regulations:
All gas appliances must be installed by a competent person in
accordance with the above regulations.
Failure to install appliances correctly could lead to prosecution.
The appliance must be installed in accordance with, and comply to, the
current: Gas Safety Regulations, IEE Regulations, Building Regulations,
Building Standards (Scotland) (Consolidation), Building Regulations
(Northern Ireland), local water by-laws, Health & Safety Document 635
(The Electricity at Work Regulations 1989) and any other local
requirements.
BUILDING REGULATIONS PART L 1A 2010
If the installation is in a new build property or is a first time installation in
an existing property, heating systems must conform to current building
regulations Part L1a.
All new heating systems in dwellings must have at least two heating
zones. Each of these zones will be operated separately by both time and
temperature controls.
The exception to this are single storey, open plan dwellings where the
living area is more than 70% of the total useable floor area. Then this
type of dwelling can be controlled as one zone.
All radiators must have TRVs fitted, where reasonable, in all rooms
except bathrooms and rooms with thermostats.
BUILDING REGULATIONS PART L 1B 2010 - BOILER REPLACEMENT
For boiler replacement on an existing system, it is not necessary to zone
the system, compliance with the zone requirements can be achieved by
a single room thermostat or programmable room thermostat.
BRITISH STANDARDS
Where no specific instruction is given, reference should be made to the
relevant British Standard codes of Practice.
BS7074:1 Code of practice for domestic and hot water supply
BS6891 Installation of low pressure gas pipe work up to 28mm (R1)
BS5546 Installation of gas hot water supplies for domestic purposes
EN12828 Central heating for domestic premises
BS5440:1 Flues and ventilation for gas appliances of rated heating not
exceeding 70kW (net) : Flues
BS5440:2 Flues and ventilation for gas appliances of rated heating not
exceeding 70kW (net) :
Air Supply
BS7593 Treatment of water in domestic hot water central heating
systems
BS6798 Installation of gas fired boilers of rated input up to 70kW (net)
Irish Standards
The relevant Irish standards should be followed, including:
• ECTI National rules for electrical installations
• IS 813:2002 for Domestic Gas Installations.
Timber framed building:
Where the boiler is to be fitted to a timber framed building the guidelines
laid down in BS5440: Part 1 and IGE "Gas Installations in Timber Frame
Buildings" should be adhered to.
Potable water:
All seals, joints and compounds (including flux and solder) and
components used as part of the secondary domestic water system must
be approved by WRAS.