Siemens SITRANS LG240 Operating Instructions Manual page 72

Guided wave radar profibus pa polished rod probe
Hide thumbs Also See for SITRANS LG240:
Table of Contents

Advertisement

Material ca-
Material seal
ble gland
insert
PA
NBR
Brass, nickel-
NBR
plated
Stainless
NBR
steel
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, stranded wire
Ʋ Stranded wire with end sleeve
Electromechanical data - version IP66/IP68 (1 bar)
Options of the cable entry
Ʋ Cable gland with integrated connec-
tion cable
Ʋ Cable entry
Ʋ Blind plug
Connection cable
Ʋ Wire cross-section
Ʋ Wire resistance
Ʋ Tensile strength
Ʋ Standard length
Ʋ Max. length
Ʋ Min. bending radius (at 25 °C/77 °F)
Ʋ Diameter
Ʋ Colour - Non-Ex version
Ʋ Colour - Ex-version
Integrated clock
Date format
Time format
Time zone, factory setting
Max. rate deviation
Additional output parameter - Electronics temperature
Range
Resolution
Deviation
Output of the temperature values
Ʋ Indication
Ʋ Output
72
4.5 ... 8.5 mm
5 ... 9 mm
0.2 ... 2.5 mm² (AWG 24 ... 14)
0.2 ... 1.5 mm² (AWG 24 ... 16)
M20 x 1.5 (cable ø 5 ... 9 mm)
½ NPT
M20 x 1.5; ½ NPT
0.5 mm² (AWG 20)
< 0.036 Ω/m
< 1200 N (270 lbf)
5 m (16.4 ft)
180 m (590.6 ft)
25 mm (0.984 in)
approx. 8 mm (0.315 in)
Black
Blue
Day.Month.Year
12 h/24 h
CET
10.5 min/year
-40 ... +85 °C (-40 ... +185 °F)
< 0.1 K
±3 K
Via the display and adjustment module
Via the respective output signal
SITRANS LG240 - Operating Instructions
Cable diameter
6 ... 12 mm
7 ... 12 mm
10 ... 14 mm
PBD-51041044

Advertisement

Table of Contents
loading

Table of Contents