Installation

Follow these steps to install the small shot kit. Because
of the variation in customer components this kit is
installed with, these instructions may not match exact
customer components. Refer to Fluid Automation F4
Series Setup and Operation manual 335028 for more
information on existing installation of parts.

Pressure Relief Procedure

Follow the Pressure Relief Procedure whenever
you see this symbol.
PRESSURIZED FLUID HAZARD
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop pumping and before
installing the kits in this manual, cleaning, checking
or servicing the equipment.
NOTE: Always place an empty container under the
prime valves and the ratio check valves before using
them to keep material from dispensing onto the system.
NOTE: There is pressure on each side of both the A and
B dosing valves. Pressure must be relieved on the
pump side and the stack side of the dosing valves.
1. To relieve pressure at the pump, turn off the fluid
automation system air slider valve. See F
F
. 2
IG
2. Open the prime ball valves for both the A and B
pumps. See F
. 3.
IG
3A8810 A
F
. 3
IG
3. To relieve pressure on the side leading out to the
stack from the dosing valves, ensure the material
outlet valves are open on the A and B side.
4. Open the ratio check valve on both the A and B
side to relieve pressure. See F
. 2.
IG
F
. 4
IG
NOTE: This procedure relieves air pressure from the
entire fluid automation system.
IG
Material Outlet Valves
Ratio Check Valves
Installation
Prime Ball
Valve