Code
570
Break % select
571
ITS auto redial time set
572
ITS auto redial line disconnection time set
573
Remote turn-on ring number
580
TAM continuous tone detection
590
FAX auto redial time set
591
FAX auto redial line disconnection time set
592
CNG transmit select
593
Time between CED and 300 bps
594
Overseas DIS detection
595
Receive error limit value
596
Transmit level set
598
Receiving Sensitivity
599
ECM frame size
717
Transmit speed select
718
Receive speed select
722
Redial tone detect
731
CPC mode
732
Auto disconnect
745
Power on film feed
763
CNG detect time for friendly reception
771
T1 timer
774
T4 timer
775
Monitoring of message transfer
784
Voice prompt
815
Sensor & VOX test
844
Original setting
852
Print test pattern
853
Top margin
874
DTMF ON time
875
DTMF OFF time
880
History list
881
Journal 2
882
Journal 3
991
Setup list
994
Journal list
995
Journal 2 list
996
Journal 3 list
998
History list
999
Service list
OK means "can set".
NG means "can not set".
Note:
Refer to SERVICE FUNCTION TABLE (P.48) for descriptions of the individual codes.
Example:
If you want to set value in the "004 Transmission report mode", press the dial key number 1,2 or 3 corresponding to the Set
Value you want to select. (1:ERROR/2:ON/3:OFF)
Function
Set Value
1:61% / 2:67%
00~99
001~999sec
01~99
1:ON / 2:OFF
00~99
001~999sec
1:OFF / 2:ALL / 3:AUTO
1:75ms / 2:500ms / 3:1sec
1:1st / 2:2nd
001~999
-15~00dBm
20~48
1: 256 byte / 2: 64 byte
1:14400 / 2:12000 / 3:9600/ 4:7200/
5:4800/ 6:2400
1:14400 / 2:12000 / 3:9600/ 4:7200/
5:4800/ 6:2400
1:ON / 2:OFF
1:A / 2:B / 3:OFF
1:350ms / 2:1800ms / 3:OFF
1:ON / 2:OFF
1:10s / 2:20s / 3:30s
1:35s / 2:60s
00~99 × 100ms
1:ON / 2:OFF
1:Start
---------
1:Normal / 2:Light / 3:Darker
---------
1~9
060~200ms
060~200ms
1:Start
---------
---------
1:Start
1:Start
1:Start
1:Start
1:Start
1:Start
55
KX-FP362BX
Default
Remote
Setting
61%
OK
05
OK
065sec
OK
10
OK
ON
OK
05
OK
065sec
OK
ALL
OK
75ms
OK
1st
OK
100
OK
-10dBm
OK
40
OK
256 byte
OK
14400bps
OK
14400bps
OK
ON
OK
A
OK
350msec
OK
ON
OK
30s
OK
35s
OK
00ms
OK
OFF
OK
---------
NG
---------
NG
Normal
NG
---------
NG
5
OK
090ms
OK
085ms
OK
---------
NG
---------
NG
---------
NG
---------
OK
---------