Annex; Tightening Torques; Tightening Torques For Type 3349 Valve With Type 3271 Or Type 3277 Actuator; Tightening Torques For Type 3349 Valve With Type 3379 Actuator - Samson 3349 Mounting And Operating Instructions

Aseptic angle valve with usp-vi diaphragm, valve with pneumatic actuator and positioner, valve combined with pneumatic piston actuator and positioner
Table of Contents

Advertisement

15 Annex

15.1 Tightening torques

15.1.1 Tightening torques for
Type 3349 Valve with
Type 3271 or Type 3277
Actuator
Table 15-1: Tightening torques for connec-
tion of plug and plug stem
Valve size
DN
NPS
6 to 25
¼ to 1
(micro-
(micro-
flow
flow
valve)
valve)
15 to 25 ½ to 1
1¼ to
32 to 65
80 to
3 to 4
100
Table 15-2: Tightening torques for connec-
tion of valve body and bonnet
Valve size
Tightening torque for screws
DN
NPS
6 to 25
¼ to 1
(micro-
(micro-
flow
flow
valve)
valve)
15 to 25 ½ to 1
1¼ to
32 to 65
EB 8048-2 EN
Tightening torque for plug
(2) and plug stem (3) in Nm
4
16
135
230
(34) in Nm
4
16
40
Valve size
DN
NPS
80 to
3 to 4
100
NOTICE
!
Risk of damage to the body screws due to
excessively high tightening torques.
Older valve versions have body screws that
are no longer suitable for the specified tight-
ening torques.
Î Make sure that the new screws are used
for all versions.
Î Contact our after-sales service for further
information.
15.1.2 Tightening torques for
Type 3349 Valve with
Type 3379 Actuator
Table 15-3: Tightening torques for connec-
tion of plug and plug stem
Valve size
DN
NPS
6 to 25
¼ to 1
(micro-
(micro-
flow
flow
valve)
valve)
15 to 25 ½ to 1
32 to 50 1¼ to 2
Tightening torque for screws
(34) in Nm
135
Tightening torque for plug
(2) and plug stem (3) in Nm
4
16
135
Annex
15-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3277373033793724

Table of Contents