Service Work For Version With Type 3379 Actuator - Samson 3349 Mounting And Operating Instructions

Aseptic angle valve with usp-vi diaphragm, valve with pneumatic actuator and positioner, valve combined with pneumatic piston actuator and positioner
Table of Contents

Advertisement

Servicing
9.6 Service work for version
with Type 3379 Actuator
See Fig. 9-5
Î Before performing any service work,
preparations must be made to the control
valve (see section 9.3).
Î After all service work is completed, check
the control valve before putting it back
into operation (see 'Testing the installed
valve' in the 'Installation' section).
Legend for Fig. 9-3 to Fig. 9-7
1
Body
2
Plug
3
Plug stem
5.1
Stem seal
5.2
Threaded bushing
6.1
Threaded pin
6.2
Retaining washer
15
Spring
19
Washer
20.3
Valve bonnet for micro-flow valve
version with Type 3379 Actuator
9-8
21
Standard valve bonnet with Type 3379
Actuator
23
Packing
24
Diaphragm
34
Screw
36
Screw plug or nipple
39
Gasket
40
Pipe
41
Bearing
42
Spacer of stem seal (micro-flow valve
version only)
43
Snap ring
EB 8048-2 EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3277373033793724