CEN-TECH 59492 Owner's Manual page 6

Shipping scale
Table of Contents

Advertisement

Calibration
N is required.lace the Scale on a flat and stable surface.
1. Place the Scale on a flat
and stable surface.
2. Press and hold the MODE and
POWER buttons until random
numbers are on the display.
3. Press POWER button again,
the screen will display "2Ero".
4. Press MODE button to choose
the weight of calibration
weight. Default is 5 lb. Press
TARE and HOLD buttons to
adjust weight of calibration
weight, if different than 5 lb.
Page 6
For technical questions, please call 1-888-866-5797.
5. Place the 5 lb. Calibration Weight
on the center of the platform.
6. Wait until "CAL" and
"PASS" are displayed.
7. If calibration is successful, the
scale will return to Weighing Mode.
Note: If calibration is unsuccessful,
repeat calibration process or have
qualified technician calibrate scale.
Note: Do Not turn Scale off
during the Calibration process.