Variable name
Meaning
_EIP2_BootpErr
Port2 BOOTP Server
Error
_EIP_IPRTblErr
IP Route Table Error
_EIP_IdentityErr
Identity Error
_EIP1_IdentityErr
CIP Communica-
tions1 Identity Error
_EIP2_IdentityErr
CIP Communica-
tions2 Identity Error
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
3 System-defined Variables Related to the Built-in EtherNet/IP Port
Function
Indicates that a BOOTP server connec-
tion failure occurred on the communica-
tions port 2.
TRUE: There was a failure to connect to
the BOOTP server (timeout).
FALSE: The BOOTP is not enabled, or
BOOTP is enabled and an IP address
was normally obtained from the BOOTP
server.
Note You can use this system-de-
fined variable only for the
NX701 CPU Units and NX102
CPU Units.
NX-series CPU Units: Indicates that the
default gateway settings or IP router ta-
ble settings are incorrect.
Or, a read operation failed.
TRUE: Setting incorrect or read failed.
FALSE: Normal
NJ-series CPU Units: Indicates that the
IP router table or hosts settings are incor-
rect. Or, a read operation failed.
TRUE: Setting incorrect or read failed.
FALSE: Normal
NX-series CPU Units: Indicates that the
identity information for CIP communica-
tions 1 (which you cannot overwrite) is in-
correct. Or, a read operation failed.
TRUE: Setting incorrect or read failed.
FALSE: Normal
NJ-series CPU Units: Indicates that the
identity information (which you cannot
overwrite) is incorrect. Or, a read opera-
tion failed.
TRUE: Setting incorrect or read failed.
FALSE: Normal
Indicates that the identity information for
CIP communications 1 (which you cannot
overwrite) is incorrect. Or, a read opera-
tion failed.
TRUE: Setting incorrect or read failed.
FALSE: Normal
Note You can use this system-de-
fined variable only for NX-ser-
ies CPU Units.
Indicates that the identity information for
CIP communications 2 (which you cannot
overwrite) is incorrect. Or, a read opera-
tion failed.
TRUE: Setting incorrect or read failed.
FALSE: Normal
Note You can use this system-de-
fined variable only for the
NX701 CPU Units and NX102
CPU Units.
Range of
Data type
values
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
Reference
page 3-44
page 3-45
3
page 3-45
page 3-45
page 3-45
3-13