Omron NJ Series User Manual page 122

Machine automation controller, cpu unit built-in ethernet/ip port
Hide thumbs Also See for NJ Series:
Table of Contents

Advertisement

3 System-defined Variables Related to the Built-in EtherNet/IP Port
Variable name
_EIP_DNSCfgErr
Meaning
DNS Setting Error
Function
Indicates that the DNS or hosts settings are incorrect. Or, a read operation failed.
TRUE: Setting incorrect or read failed.
FALSE: Normal
Data type
BOOL
R/W access
R
Usage in user pro-
Possible.
gram
*1.
With the NJ-series CPU Unit, this variable can be used with the unit version 1.11 or later.
Variable name
_EIP_BootpErr
Meaning
BOOTP Server Error
Function
NX-series CPU Units: Indicates that a BOOTP server connection failure occurred on the communications port 1.
TRUE: There was a failure to connect to the BOOTP server (timeout).
FALSE: The BOOTP is not enabled, or BOOTP is enabled and an IP address was normally obtained from the
BOOTP server.
NJ-series CPU Units: Indicates that a BOOTP server connection failure occurred.
TRUE: There was a failure to connect to the BOOTP server (timeout).
FALSE: The BOOTP is not enabled, or BOOTP is enabled and an IP address was normally obtained from the
BOOTP server.
Data type
BOOL
R/W access
R
Usage in user pro-
Possible.
gram
Variable name
_EIP1_BootpErr
Meaning
Port1 BOOTP Server Error
Function
Indicates that a BOOTP server connection failure occurred on the communications port 1.
TRUE: There was a failure to connect to the BOOTP server (timeout).
FALSE: The BOOTP is not enabled, or BOOTP is enabled and an IP address was normally obtained from the
BOOTP server.
Note You can use this system-defined variable only for NX-series CPU Units.
Data type
BOOL
R/W access
R
Usage in user pro-
Possible.
gram
Variable name
_EIP2_BootpErr
Meaning
Port2 BOOTP Server Error
Function
Indicates that a BOOTP server connection failure occurred on the communications port 2.
TRUE: There was a failure to connect to the BOOTP server (timeout).
FALSE: The BOOTP is not enabled, or BOOTP is enabled and an IP address was normally obtained from the
BOOTP server.
Note You can use this system-defined variable only for the NX701 CPU Units and NX102 CPU Units.
Data type
BOOL
R/W access
R
Usage in user pro-
Possible.
gram
3-44
*1
Retained
Not retained.
Related in-
---
structions
Retained
Not retained.
Related in-
---
structions
Retained
Not retained.
Related in-
---
structions
Retained
Not retained.
Related in-
---
structions
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.

Advertisement

Table of Contents
loading

Table of Contents