Omron NJ Series User Manual page 157

Machine automation controller, cpu unit built-in ethernet/ip port
Hide thumbs Also See for NJ Series:
Table of Contents

Advertisement

Setting
IP address setting
method
*1
IP address
Subnet mask
*1.
These settings are required if you select Fixed setting for the IP address setting method.
*2.
Refer to 4-2 Built-in EtherNet/IP Port IP Address Settings on page 4-5 for details on setting IP address-
es.
Precautions for Correct Use
For NX701 and NX102 CPU Units, you cannot set IP addresses that make the two built-in
EtherNet/IP ports belong to the same network.
 IP Address (NJ-series CPU Unit)
Setting
IP address setting
method
*2
IP address
Subnet mask
Default gateway
*1.
Refer to 4-2 Built-in EtherNet/IP Port IP Address Settings on page 4-5 for details on setting IP address-
es.
*2.
These settings are required if you select Fixed setting for the IP address setting method.
*3.
This setting is valid if you select Fixed setting for the IP address setting method.
 Default Gateway (NX-series CPU Unit)
Setting
Default gateway
*1.
If you select Obtain from BOOTP server or Fix at the IP address obtained from BOOTP server for
the IP address setting method, the default gateway obtained from a BOOTP server is enabled.
*2.
For NX701 and NX102 CPU Units, even if you are using both of port 1 and port 2, you can set the de-
fault gateway for only one of the ports.
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
5 Sysmac Studio Settings for the Built-in EtherNet/IP Port
Select one of the following IP address setting methods for the built-in
EtherNet/IP port 2.
Fixed setting
Obtain from BOOTP server.
Fix at the IP address obtained from BOOTP server.
Set the IP address for the built-in EtherNet/IP port 2.
Set the subnet mask for the built-in EtherNet/IP port 2.
*2
Select one of the following IP address setting methods for the
built-in EtherNet/IP port.
Fixed setting
Obtain from BOOTP server.
Fix at the IP address obtained from BOOTP server.
Set the IP address for the built-in EtherNet/IP port.
Set the subnet mask for the built-in EtherNet/IP port.
*2
Set the IP address of the default gateway for the built-in Ether-
*3
Net/IP port.
This setting is not required when the default gateway is not used.
Set the IP address of the default gateway for the built-in Ether-
*1
*2
Net/IP port.
This setting is not required when the default gateway is not used.
Description
*2
Description
*1
Description
Default
Fixed setting
192.168.251.1
255.255.255.0
Default
Fixed setting
5
192.168.250.1
255.255.255.0
None
Default
None
5-3