Disassembly - and Reassembly advice
Removal of the UI
1. To remove the UI push the 2 snaps inside (indicated with the red arrows):
2. Then unplug the cable.
Do not use a screwdriver, but pull it keeping the flat cable and not the connector (some force is required)
3. Click on the 4 snaps to remove the UI board protection.
,
Philips EP Series
18
Disassembly - and Reassembly advice
4. To re-mount the UI start keeping inserted first the upper part of the cover, then push it.
Make sure the 4 snaps are properly closed
,
Removal of the Grinder
1. Pull out the grinder assy
2. Remove the electric connections
Removal of the Electrovalves
1. For the upper EV pull outwards the valve holder.
2. For the lateral EV take out the 2 screws, then remove the valve.
19