Installation Instructions
Adjust the panel by turning it to the arrowed direction so that the ceiling
opening is completely covered.
Drain port
louver motor
Main body
Ceiling
Panel side sponge
Panel
Panel foam 1
Out of the wind
Figure 55
NOTICE: PRODUCT DAMAGE
 If the height of the indoor unit needs to be adjusted, you can
do so through the openings at the panel's four corners. Make
sure that the internal wiring and drainpipe are not affected
by this adjustment.
Water condensation
Figure 56
3 0 |
Refrigerant port
Into the wind
Outlet foam
Panel foam 2
Baffle
Bosch Climate 5000 Series Four Way Cassette Ductless Split Air Conditioner / Heat Pump (06.2022)
CAUTION: SLIP HAZARD
 Failure to tighten screws can cause water leakage.
Gap not allowed
Figure 57
NOTICE: PRODUCT DAMAGE
 If the unit is not hung correctly and a gap exists, the unit's
height must be adjusted to ensure proper function. The
unit's height can be adjusted by loosening the upper nut,
and adjusting the lower nut.
Hang the intake grille on the panel, and then connect the lead connectors
of the louver motor and the control box on the panel to the corresponding
connectors of the main body.
Install cover rope
Panel hook
Figure 58
Re-installed into the style grid. Reinstall the installation cover. Fix the
installation cover plate rope to the pillar of the installation cover plate, and
gently press the installation cover plate into the panel.
Figure 59
After installation, the butt plugs of display, swing, water pump and other
wire bodies must be placed in the electric control box.