Natural Gas Conversion - Maytag MGR5605W Installation Instructions Manual

30" (76.2 cm) freestanding gas ranges
Hide thumbs Also See for MGR5605W:
Table of Contents

Advertisement

Available languages

Available languages

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
To Convert Gas Pressure Regulator
1. Turn manual shutoff valve to the "closed" position.
2. Unplug range or disconnect power.
A
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply line
3. Open broiler door and remove broiler pan. The gas pressure
regulator is located in the back right hand corner of the broiler
compartment.
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
NOTE: Do not remove the spring beneath the cap.
4. Remove the cap from the gas pressure regulator using a
flat-blade screwdriver.
A. Cap

Natural Gas Conversion

5. Turn the cap over so that N or NAT is visible.
6. Reinstall the cap.
To Convert Surface Burners
1. Remove burner grate, burner caps and burners.
B
C
2. Locate the Natural gas orifice spuds for top burners in the
A
3. Remove the LP gas orifice spuds using a 7 mm combination
4. Install the Natural gas orifice spuds using a 7 mm combination
A
A. Cap
A. Burner cap
B. Burner
literature bag included with the range. Three Natural gas
spuds are stamped "149" and one "165."
wrench.
wrench.
A. Spud
B. Holder
NOTE: Depending on model, the range cooktop may be
equipped with 4 standard burners or 3 standard burners and 1
power burner. Spud size/location remain the same.
A
A
B
A
B
13