Water and air temperature probes.
Speedeo Connect is supplied with a temperature probe which is suitable for water. It is possible to mount
a second temperature probe for the air temperature used to manage the frost protection process of heated
technical rooms. The probe time can be staggered via the Temperature Menu > Calibration: (see p15)
- Once Speedeo Connect is linked to a SOLEO, the temperature values saved and displayed by
Speedeo Connect are picked up by the SOLEO.
The temperature sensor provided can also be used as an air temperature sensor.
INSTALLATION OF THE WATER TEMPERATURE PROBE
The temperature probe can be installed outside the bypass in front of the filter of the pump or in front of the
filter inlet in order to improve the reading precision.
1 - Pierce the PVC pipe (diam. 50-70 mm) to a diameter of 10 mm (3/8 inch).
2 - Remove the burrs and check the O-ring under the probe.
3 - Place the sensor in the hole, then place the clamp band in the groove and tighten.
4 - Connect wires to dedicated terminal block.
Ø 10 mm
1
INSTALLATION OF THE AIR TEMPERATURE PROBE (OPTION)
- If the air temperature probe is connected, it automatically becomes the reference value for freeze protection
management (unless Speedeo Connect is connected to a SOLEO). The air temperature probe is placed outdoors,
away from direct sunlight so that the measurement is not distorted. It can be easily moved due to its 6 m long
cable.
1 – Mount it on a wall with screws. 2 – Mount it on a horizontal bar of a grate with a cable tie.
NO
1 - Connect the cables to Inlet 2 in accordance with the diagram.
2 - Start the secured Install menu (on the main menu, press Esc and Valid at the same time for
3 secs. A star appears in the top right corner of the home screen).
3 - In the Inlets / E1-E2 sub-menu (in accordance with chosen terminal), select T° Air to indicate
that a temperature sensor is connected to the corresponding inlet.