Table 15-1 Diagnostic Codes

Code Group
Configuration
Switch Faults
(MS4800S only)
Safety Output
(OSSD) Faults
EDM Faults
Controller Fault
Setup Error
Muting Faults
Cascaded System
Faults
OMRON Scientific Technologies Inc.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
& T
ROUBLESHOOTING
I AG NO ST IC S
Error Code
Description of Error Code
21
Invalid mode selection setting
22
Configuration switch settings
changed during operation
23
Configuration switch settings
do not match
24
Corrupted EEPROM
configuration.
26
Invalid scan code setting
31
Safety outputs 1 & 2 are
shorted together
32
Safety output 1 shorted to
power
33
Safety output 2 shorted to
power
34
Safety output 1 shorted to
ground
35
Safety output 2 shorted to
ground
41
EDM circuit did not open before
transition to MACHINE RUN
State
42
EDM circuit did not open after
transition to MACHINE RUN
state
43
EDM circuit was in wrong state
during power-up
44
EDM fault at power-up
50
Control logic fault
60
Possible crosstalk
70
General muting fault
71
Mute sensors activated in the
wrong sequence
74
Mute lamp burned out or not
connected
80
Configuration error
81
Second segment or mute
module error
82
Third segment or mute module
error
83
Fourth segment or mute
module error
84
Mute module error
Corrective Action Needed
Verify switch setting. See user manual.
Verify switch setting. See user manual.
Verify switch setting. See user manual.
Reset the system configuration to
factory default.
Verify switch setting. See user manual.
Check and correct wiring of safety
outputs 1 and 2.
Check and correct wiring of safety
output 1.
Check and correct wiring of safety
output 2.
Check and correct wiring of safety
output 1.
Check and correct wiring of safety
output 2.
Check and correct EDM wiring.
Check and correct EDM wiring.
Check and correct EDM wiring.
Check start input wire or EDM function
selection.
Call Omron STI(888-510-4357) or return
receiver to Omron STI for evaluation
Possible crosstalk
Check wiring of unused mute sensors.
Check mounting of mute sensors for
correct sequence.
Check status of mute lamp.
Call Omron STI for troubleshooting
assistance (888-510-4357)
Check all cable connections. Call
Omron STI (888-510-4357)
Check all cable connections. Call
Omron STI (888-510-4357)
Check all cable connections. Call
Omron STI (888-510-4357)
Check all cable connections to mute
module. Call Omron STI (888-510-
4357)