Table of Contents

Advertisement

Available languages

Available languages

Quick Links

CENTRALINA DI CONTROLLO
LED
PLLEDCNTRHP

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for PROEL PLLEDCNTRHP

  • Page 1 CENTRALINA DI CONTROLLO PLLEDCNTRHP...
  • Page 2: Table Of Contents

    INDICE INFORMAZIONI GENERALI............................3 ISTRUZIONI DI SICUREZZA ............................3 1. CARATTERISTICHE PRINCIPALI .........................4 2. IMPOSTAZIONE ...............................4 2.1 Alimentazione: ..............................4 2.2 Requisiti di cablaggio (Cavo DMX):......................5 Connettori DMX XLR 5 poli........................6 3. VISTE ....................................7 4. ISTRUZIONI OPERATIVE............................8 4.1 Modalità di controllo DMX (Indirizzamento DMX)................8 4.2 Modalità...
  • Page 3: Informazioni Generali

    Nel continuo sforzo di migliorare la qualità dei suoi prodotti, la Proel SpA può introdurre cambiamenti tecnici nel corso della produzione. Pertanto le specifiche tecniche ed il disegno possono subire variazioni senza preavviso. La Proel SpA non è responsabile dei danni derivanti da uso improprio o diverso da quello previsto di questo prodotto.
  • Page 4: Caratteristiche Principali

    1. CARATTERISTICHE PRINCIPALI - La PLLEDCNTRHP PLLEDCNTRHP è una centralina di controllo LED ad alte prestazioni, PLLEDCNTRHP PLLEDCNTRHP utilizzata per controllare proiettori a LED da 1 Watt, come il PLLEDCLHP PLLEDCLHP PLLEDCLHP.
  • Page 5: Requisiti Di Cablaggio (Cavo Dmx)

    PLLEDCNTRHP PLLEDCNTRHP PLLEDCNTRHP PLLEDCNTRHP è disponibile sia in versione 120v che in versione 230v. Anche l’alimentatore incorporato è disponibile in due versioni: DC24V/6.5A e DC48V/3.2A . A causa delle differenze nella tensione di linea dipendenti dal luogo in cui il prodotto è utilizzato, prima di avviare il funzionamento dell’unità, è...
  • Page 6: Connettori Dmx Xlr 5 Poli

    Avvertenza Avvertenza Avvertenza Avvertenza Terminazione. Quando vengono utilizzati cavi molto lunghi, può essere necessario usare terminatore sull’ultima unità evitare malfunzionamenti. Un terminatore è una resistenza da 120 ohm e 1/4 di watt collegata tra i poli 2 e 3 di un connettore XLR maschio (DATA + e DATA -).
  • Page 7: Viste

    3. VISTE Pannello frontale Pannello frontale Pannello frontale Pannello frontale 1. Gruppo Dip 1. Gruppo Dip- - - - Switch: Switch: 1. Gruppo Dip 1. Gruppo Dip Switch: Switch: Gruppo di dip switch da 10 a sinistra: GRUPPO A Gruppo di dip switch da 6 a destra: GRUPPO B. GRUPPO A GRUPPO B 2.
  • Page 8: Istruzioni Operative

    Pannello posteriore Pannello posteriore Pannello posteriore Pannello posteriore 1. Alimentazione AC110~120V(3.2A) /AC220~240V(1.2A), 50~60Hz. 2. Selettore di tensione: AC120V/230V selezionabile. 4. ISTRUZIONI OPERATIVE 4.1 Modalità di controllo DMX (Indirizzamento DMX) DMX è una sigla che sta per Digital Multiplex, un linguaggio binario universale utilizzato come forma di comunicazione tra dispositivi intelligenti.
  • Page 9: Modalità Stand Alone

    4.2 Modalità STAND ALONE La modalità STAND ALONE viene attivata portando il dip-switch n.10 del GRUPPO A in posizione " ". Questa modalità ha ulteriori sottomodalità con molte funzioni, come tempo di dissolvenza, velocità di sequenza e programmi preimpostati. 4.3 Impostazione del tempo di dissolvenza 1.
  • Page 10: Regolazione Della Velocità Della Sequenza

    4.4 Regolazione della velocità della sequenza 1. Attivare la modalità STAND ALONE. 2. Spostare quindi le levette 4, 5 e 6 del GRUPPO A per impostare la velocità di sequenza desiderata. 4.5 Selezione dei programmi preimpostati 1. Attivare la modalità STAND ALONE. 2.
  • Page 11: Impostazione Della Modalità Di Caricamento Del Segnale In Uscita

    3.) La modalità di proiezione del gruppo 3 si attiva posizionando il dip-switch 1 su " " e il dip-switch 2 su " ". Si hanno così la proiezione del gruppo 3 e 2 emissioni identiche distribuite su 3 gruppi. L’emissione del 1~2 è identica, così come quella dei gruppi 3~4 e 5~6.
  • Page 12: Specifiche Tecniche

    l’intensità della luce in uscita. Ogni dip-switch rappresenta un valore binario. Dip-switch 1 = livello intensità 1 Dip-switch 2 = livello intensità 2 Dip-switch 3 = livello intensità 4 Dip-switch 4 = livello intensità 8 Dip-switch 5 = livello intensità 16 Dip-switch 6 = livello intensità...
  • Page 13: Dimensioni

    6. DIMENSIONI Vista frontale Vista posteriore Vista dall’alto...
  • Page 14: Appendice Schema Di Connessione

    APPENDICE SCHEMA DI CONNESSIONE Dettaglio schema di connessione del sistema LED PLLEDCLHP Dettaglio schema di connessione del sistema LED PLLEDCLHP Dettaglio schema di connessione del sistema LED PLLEDCLHP Dettaglio schema di connessione del sistema LED PLLEDCLHP...
  • Page 15 TABLE OF CONTENTS GENERAL INFORMATION ............................16 1. MAIN FEATURES..............................17 2. SET UP ..................................17 2.1 Power Supply:...............................17 2.2 Data Cable (DMX Cable) Requirements: ....................18 2.3 Five Pin XLR DMX Connectors........................18 3. PRODUCT LAYOUT & FUNCTIONS ........................19 4. OPERATION GUIDE..............................20 4.1 DMX Control Mode(DMX Addressing)....................20 4.2 Stand Alone Mode ............................21 4.3 Setting fade time ............................21 4.4 Adjusting chase speed ..........................22...
  • Page 16: General Information

    Please note that due to continuous product development, the specifications are subject to change without notice. Whilst every care is taken in the preparation of this manual Proel SpA reserves the right to change specifications in the course of the product improvement. The publishers cannot be held responsible for the accuracy of the information herein, or any consequence arising from them.
  • Page 17: Main Features

    1. MAIN FEATURES PLLEDCNTRHP is a HP LED driver unit, specially used to drive 1 Watt high power LED fixtures, such as PLLEDCLHP. Also PLLEDCNTRHP is engaged as a combination of a control interface and tension provider for 1Watt high power LED fixtures.
  • Page 18: Data Cable (Dmx Cable) Requirements

    2.2 Data Cable (DMX Cable) Requirements: Connect the PLLEDCNTRHP PLLEDCNTRHP PLLEDCNTRHP and your fixtures together using standard 3 PLLEDCNTRHP pin DMX cables. The PLLEDCNTRHP PLLEDCNTRHP uses PLLEDCNTRHP PLLEDCNTRHP DMX-512 protocol to operate your fixtures.
  • Page 19: Product Layout & Functions

    3. PRODUCT LAYOUT & FUNCTIONS Front Panel Layout Front Panel Layout Front Panel Layout Front Panel Layout 1. Dip Switches (10 1. Dip Switches (10 1. Dip Switches (10 1. Dip Switches (10- - - - way and 6 way and 6 way and 6 way and 6- - - - way): way):...
  • Page 20: Operation Guide

    Rear Panel Layout Rear Panel Layout Rear Panel Layout Rear Panel Layout 1. Power Input: AC110~120V(3.2A) /AC220~240V(1.2A), 50~60Hz. 2. Voltage Selector: AC120V/230V optional by this voltage selector. 4. OPERATION GUIDE 4.1 DMX Control Mode(DMX Addressing) DMX is short for Digital Multiplex. This is a universal binary language used as a form of communication between intelligent fixtures.
  • Page 21: Stand Alone Mode

    4.2 Stand Alone Mode The Stand Alone Mode is engaged in by flipping the dip-switch 10 to the "OFF" position. And this mode includes sub-modes with many functions, such as fade time, chasing speed, built-in programs. 4.3 Setting fade time 1.
  • Page 22: Adjusting Chase Speed

    4.4 Adjusting chase speed 1. The Stand Alone Mode enables; 2. Thus, flip the dip-switch 4,5 & 6(10-way Function Dip Switch)to adjust a desired level for chasing speed. 4.5 Selecting Built-in programs 1. The Stand Alone mode enables; 2. Thus, flip the dip-switch 7,8 & 9 (10-way Function Dip Switch) TO select the desired program 4.6 Output Group Mode Setting In the function, the dip-switch 1&...
  • Page 23: Output Loading Mode Setting

    3.) 3 Group Output Mode is engaged by flipping the dip-switch 1 to the " " position and the dip-switch 2 to the " " position, has 3 group output and has 2 identical outputs distributed over 3 groups, Output1~2 is identical, Output 3~4 is identical and Output 5~6 is identical.
  • Page 24: Manual Dimmer Mode

    4.8 Manual Dimmer Mode In Manual Dimmer Mode, it allows to manually control overall output intensity level. Flip the dip-switch 6 of the 6-way Mode Dip Switch to the "ON" position and the Manual Dimmer Mode is engaged. In this function, the dip- switch1~8 of the 10-way Function Dip Switch is used to set overall output intensity.
  • Page 25: Physical Dimensions

    6. PHYSICAL DIMENSIONS Frontal View Back View Top View...
  • Page 26: Appendix: System Connection Diagram

    7.APPENDIX: SYSTEM CONNECTION DIAGRAM Detail wiring diagram for PLLEDCLHP LED system Detail wiring diagram for PLLEDCLHP LED system Detail wiring diagram for PLLEDCLHP LED system Detail wiring diagram for PLLEDCLHP LED system...

This manual is also suitable for:

8032496406655

Table of Contents