Chapter 2 Ie-703002-Mc Setting; Settings Of Jp2, Sw1, And Sw2 - NEC IE-703003-MC-EM1 Preliminary User's Manual

In-circuit emulator option board
Table of Contents

Advertisement

This chapter describes settings of the IE-703002-MC when the IE-703003-MC-EM1 is connected.
All settings are performed using the jumper and switches in the pod of the IE-703002-MC.
For the location of the pod, jumper, and switches, refer to the IE-703003-MC User's Manual Hardware.

2.1 Settings of JP2, SW1, and SW2

These jumper and switches set the clock. Set the jumper (JP2) and switches (SW1, SW2) depending on the use.
Remark The factory-set JP2 setting in the pod is as shown
in the diagram at right. (The numbers 1, 2, 7, 8
are the jumper pin numbers printed on the board.)
Setting of clock supply source
Supply method of clock
Internal clock
PLL mode
Direct mode (input × 1/2)
Target clock
PLL mode
Direct mode (input × 1/2)
CHAPTER 2
IE-703002-MC SETTING
Table 2-1. Settings of JP2, SW1, and SW2
JP2 setting in pod
5 × multiplication
(input × 5)
7
1 × multiplication
8
(input × 1)
5 × multiplication
(input × 5)
7
1 × multiplication
8
(input × 1)
7
1
8
2
Jumper contact
Setting of clock mode
SW1 setting in pod
(PLLSEL setting)
ON
1
OFF
2
Don't care
ON
1
OFF
2
Don't care
SW2 setting in pod
(CKSEL setting)
OFF
ON
OFF
ON
9

Advertisement

Table of Contents
loading

Table of Contents