Theben Timeguard PDFM1500 Installation & Operating Instructions Manual
Theben Timeguard PDFM1500 Installation & Operating Instructions Manual

Theben Timeguard PDFM1500 Installation & Operating Instructions Manual

360 flush mount wall pir light controller

Advertisement

Quick Links

360° Flush Mount Wall
PIR Light Controller
Model: PDFM1500

Advertisement

Table of Contents
loading

Summary of Contents for Theben Timeguard PDFM1500

  • Page 1 360° Flush Mount Wall PIR Light Controller Model: PDFM1500...
  • Page 2: General Information

    1. General Information These instructions should be read carefully and retained for further reference and maintenance. 2. Safety • Before installation or maintenance, ensure the mains supply to the PIR sensor is switched off and the circuit supply fuses are removed or the circuit breaker turned off.
  • Page 3: Selecting A Location

    4. Selecting a Location • The motion detector has a number of detection zones, at various vertical and horizontal angles as shown (see diagram “A”). • The best all-round coverage is achieved with the unit mounted at the optimum height of 3m. •...
  • Page 4 5. Installation More sens • Ensure the mains supply is switched off and the circuit supply fuses are removed or the circuit breaker turned off. Up to 3m Presence Detection Side View • An isolating switch should be installed to enable the power to be switched ON and OFF for maintenance purposes.
  • Page 5 Time On Time On Dusk/Daw n settin g settin g Diagram C Diagram D Cable clamp Wiring cover Levering area Cable clamp Time On Time On Dusk/Daw n Wiring cover settin g settin g Levering area Time On Time On Dusk/Daw n settin g settin g...
  • Page 6: Connection Diagram

    6. Connection Diagram • Connect cables to the terminal block as follows; Cable clamp Wiring cover ISOLATION SWITCH 230V AC 50Hz Sensor LOAD MAINS SUPPLY Locating springs fitted position 230V AC 50Hz Mains Supply Load Min 12mm Live (Brown or Red) to L Max 20mm Switch Live (Brown or Red) to L1 Neutral (Blue or Black) to N...
  • Page 7 7. Setting Up Walk Test Procedure HELPLINE • Turn the power to the unit ON. The lamp will immediately illuminate as the unit goes through its “warm-up” period. After approximately 020 8450 0515 1 minute the lamp will extinguish. This indicates the unit is wired correctly and the unit is in Test Mode.
  • Page 8 Setting Up for Automatic Operation • When walk tests are complete, the unit can be adjusted for automatic operation. • The TIME setting controls how long the unit remains illuminated following activation and after all motion ceases. • Use a thin flat blade screwdriver to make adjustments. •...
  • Page 9: Troubleshooting

    8. Troubleshooting Problem Solution • The lamp stays Cover PIR lens with a thick cloth. If the light turns out, ON all the time check detection area for heat or reflective source. at night. If the light stays ON, check wiring (See section 6. Connection Diagram).
  • Page 10 • The PIR sensor will The level of ambient light in the area may be too bright not operate at night to allow operation at the current DUSK setting. During the hours of darkness, adjust the DUSK control slowly clockwise until the lamp illuminates (See section 7.
  • Page 11: Year Guarantee

    3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge.
  • Page 12 If you experience problems, do not immediately return the unit to the store. Telephone the Timeguard Customer Helpline; HELPLINE 020 8450 0515 or email helpline @ timeguard.com Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query. For a product brochure please contact: Timeguard Limited.