Chapter 2
Replacing Cards in the Cisco 3230 ISR Rugged Enclosure
Replacing the FESMIC
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
OL-15983-01
Get user manuals:
See SafeManuals.com
To replace the FESMIC, follow these steps:
If WMIC 3 is present, remove WMIC 3 and WMIC 2 as one unit. If only WMIC 2 is present, remove it.
Disconnect the LED cable from the back of the FESMIC.
Remove the FESMIC.
Make sure that the rotary switch on the new FESMIC (see
on the SMIC.
For example, if the SMIC rotary switch is set to 1, then set the FESMIC switch to 0, and vice versa.
Figure 2-8
FESMIC and SMIC Rotary Switches
1
FESMIC rotary switch.
Verify that all ISA and PCI connector pins on the new FESMIC are straight and not bent.
Connect the new FESMIC card to the SMIC card by aligning the bus headers and firmly pressing the
cards together.
Be sure not to bend any exposed pins on the card while squeezing the cards together.
Note
Connect WMIC 2 (or WMIC 2 and WMIC 3 as one unit) to the FESMIC card as described in the
a New WMIC" section on page
Connect the LED cable to the back of the FESMIC.
Figure
2
SMIC rotary switch.
2-7.
Cisco 3200 Series Router Hardware Upgrade Guide
Card Replacement Process
2-8) is set opposite to the rotary switch
1
2
"Adding
2-9