NETWORK CONFIGURATION
APPENDIX C
NETWORK CONFIGURATION
C.1

Single-Head System Network Configuration

The Subsea Sonar Processor (SSP) is at delivery configured as follows:
The CFE laptop/PC which runs the Sonar User Interface (SUI) should in standard systems be
configured in the IP range 10.11.10.3-10.11.10.255 in the same subnet as the SSP.
C.2

Change IP Configuration

The IP configuration can be changed from the SUI installed on the CFE laptop/PC:
1.
Click the Application Settings
button in the top right corner of
the Sonar UI.
2.
Unfold the Sonar network
connections setting.
3.
If the connection has been
established, the Computer name
is already stated; if not, enter
SN+serial number of the SSP.
Please find the serial number on
the label on the SSP.
SeaBat T-Series Subsea Operator's Manual
Version 7

Table 20: IP Configuration for SSP

Network port
LAN 1/Host
IP address
10.11.10.1
Subnet mask
255.255.255.0
Page 111
LAN 2
10.11.10.2
255.255.255.0
January 31, 2019