Hitachi Highly 
Rollkolbenverdichter
Rotary Compressors
Spezifikation
Installation Manual
WHP05600VUKQA7JG6
R410A/ R454C/ R454B/ R134a
14,1 cm3/rev
1000 - 7200 min-1
RIES GmbH, Rudolf-Diesel-Str. 10, D 64569 Nauheim, GERMANY
Phone: +49 6152 9741 0, Fax: +49 6152 9741 21, Email: info@ries-gmbh.de, Website: www.ries-gmbh.de
2021-1-19

Advertisement

loading

Summary of Contents for Hitachi Highly WHP05600VUKQA7JG6

  • Page 1 Hitachi Highly  Rollkolbenverdichter Rotary Compressors Spezifikation Installation Manual WHP05600VUKQA7JG6 R410A/ R454C/ R454B/ R134a 14,1 cm3/rev 1000 - 7200 min-1 RIES GmbH, Rudolf-Diesel-Str. 10, D 64569 Nauheim, GERMANY Phone: +49 6152 9741 0, Fax: +49 6152 9741 21, Email: info@ries-gmbh.de, Website: www.ries-gmbh.de...
  • Page 2 Table of Contents 1. WHP05600VUKQA7JG6 Specification —————1~4 Application Compressor specifications Motor parameters List of parts and drawings General characteristics Standards for the use of special compressors for heat pump water heaters ———5~15 Acceptance Basis for acceptance Four, drawings ———————17~28 Five, specification ————29 revision experience...
  • Page 3: Specification Of Compressor

    SUBJECT Model WHP05600VUKQA7JG6 PAGE:1/29 SPECIFICATION 1. SCOPE This specification is applied to SHANGHAI HIGHLY Heat pump water heater compressor. SPECIFICATION OF COMPRESSOR 2.1 Model WHP05600VUKQA7JG6 2.2 Power source inp ut to HIGH LY inverter Rated Voltage/Frequency/Phase 220V/1/50Hz 2.3 Application Heat pump water heater 2.4 Refrigerant R410A/R454C/R454B/R134a 2.5 Compressor Cooling...
  • Page 4: Refrigerant Charge

    SUBJECT Model WHP05600VUKQA7JG6 PAGE:2/29 SPECIFICATION Heating capacity COP= Motor input 2.8 Allowable frequency range 1000~7200rpm 2.9 Allowable amount of refrigerant charge 1250g 2.10 Amount of oil charge 480±20 ml(Initial) 2.11 Oil HAF68D1/HAF68D1U/ALPHA68HES or equivalent 2.12 Space volume of inner case 1200 ml 2.13 Net weight 9.4kg incl.oil...
  • Page 5 SUBJECT Model WHP05600VUKQA7JG6 PAGE:3/29 SPECIFICATION MOTOR PARAMERER Project Parameter Description Rotor Pole(Pole) 6 electrodes 9 slots concentrated winding Mechanical Frequency , Relating to VDCmax of Inverter Rated Frequency Range(Hz) 16.7-120 Peak Current,at130℃,-5% Demagnetizing Rate Demagnetizing Curren(A) 21.6 Sheet 1 Inductance Ld( mH) ——...
  • Page 6 SUBJECT Model WHP05600VUKQA7JG6 PAGE:4/29 SPECIFICATION 4. PARTS AND DRAWING LIST PARTS NAME QTY/SET DRAWING NO. REMARKS Compressor 4CYCD0*** Dimensioned sketch Mounting 4CYC00851 Rubber grommet Parts 4CYC00940 Bolt (M8) Electrical Terminal cover 4CYC01043 Parts Gasket 4CYC01044 Sleeve 4CYC01042 3CYC00004 4CYC00174 Rubber Washer 4CYC01045 Thermostat 4CYC01426...
  • Page 7 HEAT PUMP WATER HEATER COMPRESSOR CRITERIA FOR LONG LIFE PAGE:5/29 SYSTEM COMPRESSOR CRITERIA 1 Strictly observe the specification The compressor should be used in specifications written in this “compressor specification” and not be used in specifications outside it. Moreover, accessories should be specified parts used in specified way, service must use specified parts too.
  • Page 8 HEAT PUMP WATER HEATER COMPRESSOR CRITERIA FOR LONG LIFE PAGE:6/29 SYSTEM Table 2 Item Operating Envelope Refrigerant R454B R134a R410A R454C Discharge pressure 4.762 MAX 3.465 MAX 4.439 MAX 2.633 MAX MPa{kgf/cm (condensing (condensing (condensing (condensing temperature temperature temperature temperature :<70℃)...
  • Page 9 HEAT PUMP WATER HEATER COMPRESSOR CRITERIA FOR LONG LIFE PAGE:7/29 SYSTEM R 4 5 4 C - 3 5 - 3 0 - 2 5 - 2 0 - 1 5 - 1 0 Evaporating Temp.(℃) raph 1(b) Condensing temperature 75℃...
  • Page 10 HEAT PUMP WATER HEATER COMPRESSOR CRITERIA FOR LONG LIFE PAGE:8/29 SYSTEM 5 Current limitation Current peak among motor terminals(include instantaneous current peak)should be below 21.6A(at130℃) in order to prevent magnet in motor from demagnetization. 6 Pressure difference between suction and discharge In all allowable rotational speed range, the difference of pressure should be more than 0.39MPa{4kgf/cm }.
  • Page 11 12 Start-stop frequency The frequency should be less than 6 times per hour. Operating time from start to stop should be more than 3 minutes. Stopping time should be more than 3minutes. But oil level should be met to item 8. Suction and discharge pressure should balance completely before restarting. 13 Rate of rotational speed change The rate of compressor rotational speed (acceleration) should be less than 133min /s, But if...
  • Page 12 HEAT PUMP WATER HEATER COMPRESSOR CRITERIA FOR LONG LIFE PAGE:9/29 SYSTEM 18 Liquid refrigerant return limitations (1) Liquid refrigerant level in s-tank should be lower than the top of s-pipe in s-tank.(see chart at right) (2) There should not exist noise of the liquid refrigerant compression, current and vibrancy increase.
  • Page 13: Compressor Mounting

    HEAT PUMP WATER HEATER COMPRESSOR CRITERIA FOR LONG LIFE PAGE:10/29 SYSTEM 24 Miscellany (1) The compressor should be carried carefully to avoid drop, drag ,impact and should not apply partial force on projection parts such as pipe, hermetic terminals, foot during carrying and processing. (2) The compressor should not be operated to form a vacuum and to absorb air.
  • Page 14 HEAT PUMP WATER HEATER COMPRESSOR CRITERIA FOR LONG LIFE PAGE:12/29 SYSTEM (14) SHEC will not take any responsibility against accident that is caused by the accessories equipped by yourselves. (15) The hermetic terminals of compressor should not be inserted slantingly and not be applied twisting force after inserting so as to avoid reducing of terminal fixed force.
  • Page 15 HEAT PUMP WATER HEATER COMPRESSOR CRITERIA FOR LONG LIFE PAGE:14/29 SYSTEM (21) Use the refrigerant of specified brand. When the refrigerant not specified used, it will possibly cause trouble of the performance and reliability of the compressor by the impurities in the refrigerant. (22) The lead wires should be connected to hermetic terminals without being touched on the surface of the compressor.
  • Page 16 HEAT PUMP WATER HEATER COMPRESSOR CRITERIA FOR LONG LIFE PAGE:15/29 SYSTEM 25.3 Eliminate all system contaminants such as trichlorethylene, alkalies, soap, acid, oil & washing fluid used at machining the heat exchanger tubes. 25.4 Purge parts with dry nitrogen or dry air to remove remains in parts (dust, detergent,etc.) before assembly of system..
  • Page 17 Check upon Delivery PAGE:16/29 1. Basis for Checking upon Delivery The Performance test will be carried out in accordance with this “compressor Specification”. The Safety Performance in accordance with GB4706.1 Safety of household and Similar electrical appliances General requirements and GB 4706.17 Safety Of household and similar electrical appliances Particular requirements for Motor-compressor.
  • Page 19 18/29...
  • Page 20 19/29...
  • Page 21 20/29...
  • Page 22 21/29...
  • Page 23 22/29...
  • Page 24 23/29...
  • Page 25 24/29...
  • Page 26 25/29...
  • Page 27 26/29...
  • Page 28 26/29 Compressor running speed range: Min 1000min ~Max 7200min Rotational speed Pd limit (MPa) (rpm) R410A R454C R454B R134a 1000 2.73 1.80 2.55 1.148 2100 4.76 3.47 4.44 2.633 5000 4.76 3.47 4.44 2.633 7200 3.51 2.31 3.28 1.528 1000~1800 min...
  • Page 29 27/29...
  • Page 30 30/31 Diagramm 3 Instruktionen für Drehzahländerungen bei DC Inverter Rotary Kompressoren im niedrigen Verdampfungsbereich Bemerkungen: DC Rotaray Kompressoren für Niedrigtemperaturbereich und Drehzahländerung dargestellt in den Darstellungen 1 -3, Drehzahländerungsfrequenz 1Hz/s, minimum und maximum min-1 wie dargestellt in dieser technischen Anforderung. (von 0 min-1 zu max.
  • Page 31 29/29 Specification Revision Record Page in Conclusion Date Revision Reason Spec Date...