CONTENTS WHP07600PSDPC9KQ SPECIFICATION ————— 1~4 SCOPE SPECIFICATION OF THE MODEL THE PARAMETER OF MOTOR CHARACTERISTICS PARTS AND DRAWING LIST HEAT PUMP WATER HEATER COMPRESSOR CRITERIA —— 5~15 ——————— 16 CHECK UPON DELIVERY BASIS FOR CHECKING UPON DELIVERY RULE FOR CHECKING UPON DELIVERY ———————————...
S U B J E C T M o d e l W H P 0 7 6 0 0 P S D P C 9 K Q S P E C I F I C A T I O N PAGE:1/30 SCOPE T h i s s p e c i f i c a t i o n i s a p p l i e d to SHANGHAI HIGHLY Heat pump water heater...
*.COP= Heating capacity Motor input *.Rated Capacity and input are measured with HITACHI inverter circuit by secondary Refrigerant calorimeter Methods of JIS B8606 by SHANGHAI HIGHLY Electrical Appliances Co., Ltd. Allowable capacity should be more than 95% of the rated capacity and allowable input should be less than 107% of rated motor input.
S U B J E C T S P E C I F I C A T I O N PAGE:4/30 M o d e l W H P 0 7 6 0 0 P S D P C 9 K Q PARTS AND DRAWING LIST PARTS NAME QTY/SET...
Page 7
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:5/30 COMPRESSOR CRITERIA 1 Strictly observe the specification The compressor should be used in specifications written in this “compressor specification”...
Page 8
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:6/30 The compressor should be continuously oiled back, and there should be no oil storage part in the refrigeration system configuration.
Page 9
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:7/30 raph 1 图 1 Condensing temperature 70℃...
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:8/30 8 Discharge pipe temperature Discharge pipe temperature is measured at a distance 300mm from the surface of compressor and should be less than 110℃.
Page 11
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:9/30 14 Impurities in refrigerating system (1)The weight of residue on the inside surface of the heat exchanger and tube should be less than 0.01g/m .
Page 12
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:10/30 18 Purge parts with dry nitrogen or dry air to remove remains in parts (dust, detergent, etc.) before assembly of system.
Page 13
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:11/30 Moving tubes to the moving parts; minimum clearance 12.7mm(1/2”) Moving tubes to non-moving parts;...
Page 14
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:12/30 (6)The compressor can’t be used in the place with corrosive atmosphere such as hot spring and chemical warehouse.
Page 15
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:13/30 (14) SHEC will not take any responsibility against accident that is caused by the accessories equipped by yourselves.
Page 16
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:14/30 It is necessary to install a dryer to dehumidify the residual moisture mixed in the refrigerant in the cycling system.
Page 17
H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A PAGE:15/30 (27)The fuse or/and breaker should be equipped in the main circuit. (28) The thickness of the refrigerating system using tube the tube thickness as followed external diameter(mm)
C h e c k u p o n D e l i v e r y PAGE:16/30 1. Basis for Checking upon Delivery The Performance test will be carried out in accordance with this “compressor Specification”. The Safety Performance in accordance with GB4706.1 Safety of household and similar electrical appliances General requirements and GB 4706.17 Safety of household and similar electrical appliances Particular requirements for motor-compressor.