Dry Operation - Fujitsu AO G36KBTB Series Service Instruction

1 phase type room air conditioner
Hide thumbs Also See for AO G36KBTB Series:
Table of Contents

Advertisement

1-3. Dry operation

The compressor rotation frequency shall change according to the temperature, set temperature, and
room temperature variation which the room temperature sensor of the indoor unit has detected as
shown in the table below.
Zone is defined by set temperature and room temperature.
• Compressor frequency range
Connected model name
AOHG36KBTB
AOHG45KBTB
AOHG54KBTB
• Compressor control based on room temperature
1-3. Dry operation
Outdoor temperature zone
Room temperature drops
X zone
Ts+0.5°C
J zone
Ts
-1.5°C
Y zone
X zone
J zone
Y zone
X zone
J zone
Y zone
Room temperature rises
Ts: Set temperature
- (01-6) -
Unit: rps
Operating frequency
32
32
0
33
33
0
Ts+1.5°C
Ts-0.5°C
1. Compressor frequency control

Advertisement