• Powerful operation
13 minutes later:
• 10 °C HEAT operation
 Moisture return prevention control (cooling and dry mode)
Switch the airflow AUTO at cooling mode, and the indoor fan motor will run as shown below.
Compressor
Indoor fan
setting airflow
Indoor fan speed
S-LOW
3-1. Indoor fan control
Indoor heat exchanger
temperature rises
42°C
39°C
LOW
or setting fan mode*
37°C
Cool air prevention
30°C
Indoor heat exchanger
temperature rises
42°C
39°C
LOW
or setting fan mode*
37°C
LOW
or setting fan mode*
30°C
LOW
or setting fan mode*
Indoor heat exchanger
temperature rises
39°C
On
Off
Off
10
30
60
Indoor heat exchanger
POWERFUL
temperature drops
HIGH
S-LOW
Indoor heat exchanger
POWERFUL
temperature drops
HIGH
Indoor heat exchanger
temperature drops
AUTO
LOW
180
60
180
- (04-23) -
37°C
34°C
32°C
24°C
37°C
34°C
32°C
24°C
34°C
60
10
30 (sec)