Panasonic Lumix DMC-LS1S Service Manual page 23

Table of Contents

Advertisement

Attribute
HARD
SOFT
- 5. How to returned to Normal Display:
NOTE:
The error code can not be initialized by the unit only.
PDF created with pdfFactory Pro trial version
Main item
Sub item
VENUS A/
Flash
D
FLASH
FLASH
ROM /
ROM /
(EEPROM
(EEPROM
/ Area)
/ Area)
SYSTEM
RTC
CPU
Reset
Card
Card
Stop
CPU, /
ASIC hard
Monitor
Memory
Built-in /
memory
Turn the power off and on, to exit from Error code display
mode.
Error code
High 4
Low 4
bits
bits
2000
0000
Flash charging error.
IC6001-(13) signal line or Flash charging circuit
2B00
0001
EEPROM read error
IC6002 (FLASH ROM)
0002
EEPROM write error
IC6002 (FLASH ROM)
2C00
0001
SYSTEM IC initialize failure error
Communication between IC6001 (VENUS PLUS)
IC9101 (SYSTEM)
3000
0001
NMI reset
|
Non Mask-able Interrupt
0007
(30000001-30000007 are caused by factors)
3100
0001
Card logic error
SD card data line or IC6001 (VENUS PLUS)
0002
Card physical error
SD card data line or IC6001 (VENUS PLUS)
0003
Read error
SD card data line or IC6001 (VENUS PLUS)
0004
Write error
SD card data line or IC6001 (VENUS PLUS)
0005
Format error
SD card data line or IC6001 (VENUS PLUS)
3800
0001
Camera task finish process time out.
Communication between Lens system and IC6001
(VENUS PLUS)
0002
Camera task invalid code error.
IC6001 (VENUS PLUS)
0100
File time out error in recording motion image
IC6001 (VENUS PLUS)
0002
File data send error in recording motion image
IC6001 (VENUS PLUS)
1000
AF frame movement check time out.
IC6001 (VENUS PLUS)
3900
0005
Built-in memory format error
FLASH ROM data line or IC6001 (VENUS PLUS)
23