Lens drive
OIS
C.B./Zoom
Zoom
Focus
Error code
High 4
Low 4
bits
bits
1800
1000
PSD (X) error. Hall element (X axis) position
error in OIS unit.
OIS Unit
2000
PSD (Y) error. Hall element (Y axis) position
error in OIS unit.
OIS Unit
3000
GYRO (X) error. Gyro (IC7102: X axis) detect
Main C.B.A..
IC7102 (Gyro element) or IC6001 (VENUS PLUS)
4000
GYRO (Y) error. Gyro (IC7101: Y axis) detect
Main C.B.A..
IC7101 (Gyro element) or IC6001 (VENUS PLUS)
5000
MREF error (Reference voltage error).
IC7002 (LENS drive) or IC6001 (VENUS PLUS)
6000
Drive voltage (X) error.
VENUS PLUS AD value error, LENS Unit, LENS
breaks etc.
7000
Drive voltage (Y) error.
VENUS PLUS AD value error, LENS Unit, LENS
breaks etc.
0100
HP Low detect error (C.B. encoder (full retract)
always Low detect).
FP9001-(23) signal line or IC6001 (VENUS PLUS)
0200
HP High detect error (C.B. encoder (full retract)
always High detect).
FP9001-(23) signal line or IC6001 (VENUS PLUS)
0300
ENC1 detect error (C.B. motor encoder detect
FP9001-(3) signal line or IC6001 (VENUS PLUS)
0400
ENC2 detect error (C.B. motor encoder detect
FP9001-(5) signal line or IC6001 (VENUS PLUS)
0010
HP Low detect error (Zoom encoder always Low
detect error).
FP9001-(3, 5) signal line or IC6001 (VENUS PLUS)
0020
HP High detect error (Zoom encoder always
detect error).
FP9001-(3, 5) signal line or IC6001 (VENUS PLUS)
0030
ENC1 detect error (Zoom encoder detect error).
FP9001-(3) signal line or IC6001 (VENUS PLUS)
0040
ENC2 detect error (Zoom encoder detect error).
FP9001-(5) signal line or IC6001 (VENUS PLUS)
0001
HP Low detect error (Focus encoder always
detect error).
FP9001-(23) signal line or IC6001 (VENUS PLUS)
0002
HP High detect error (Focus encoder always
detect error).