I DISASSEMBLY PROCEDURE
*
If you remove filament tapes for disassembling, be sure to apply them on the same condition as before at the time
of reassembling.
1.
Upper Case Assembly (Time required: about
4 min)
1-1
Lay the unit upside down and remove the two (2)
screws marked [170] and the seventeen (17) screws
marked [180]. (Fig.1)
[180]
[170]: Truss Head Screw 4.0X16 MFZN2BL (V6207400)
[180]: Truss Head Tapping Screw-B 4X25 MFZN2BL (VV685800)
[330d]
PN
D-JACK
[150a]
[160b]
[140]: Bind Head Tapping Screw-B 3.0X8 MFZN2BL (EP600190)
[150]: Bind Head Tapping Screw-1 3.5X12 MFZN2Y (EP030240)
[160]: Bind Head Tapping Screw-1 4.0X14 MFZN2Y (EP040230)
[190]: Pan Head Screw 5.0X25 MFZN2YPW (VV040700)
[330]: Bind Head Tapping Screw-B 3.0X8 MFZN2Y (EP600250)
[180]
[170]
[180]
(Fig. 1)
[330c]
AM
[140]
[330b]
[150b]
[160a]
[330a]
[190]
(Fig. 3)
1-2
Lay the unit right side up and open the upper case
assembly. (Fig.2)
1-3
Remove the screw marked [150a]. The upper case
assembly can then be removed. (Fig.3)
*
When reinstalling the upper case assembly, identify
the fixing point by fitting the three dowels into
holes on the keybed. (Fig.4)
[170]
[180]
Shield Cover
[150c]
DM
[190]
(Fig. 2)
[160b]
Dowel
Hole
(Fig. 4)