2. Specification
Type
Model Name
Sound Pressure Level
Sound
Sound Power Level
Net Weight
Shipping Weight
External
Dimension
Net Dimensions (WxHxD)
Shipping Dimensions (WxHxD)
Casing
Material
NOTE
• Specifications may be subject to change without prior notice.
• 1)* Capacities are based on (Equivalent refrigerant piping : 5m, Level differences : 0m)
- Cooling : Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB, 24°C WB
- Heating : Indoor temperature : 20°C DB, 15°C WB / Outdoor temperature : 7°C DB, 6°C WB
• 2)* Select wire size based on the value of MCA
• 3)* Sound pressure level is obtained in an anechoic room.
- Sound pressure level is a relative value, depending on the distance and acoustic environment.
- Sound pressure level may differ depending on operation condition.
- dBA = A-weighted sound pressure level
- Reference acoustic pressure 0 dB = 20uPa
• 4)* Sound power level is an absolute value that a sound source generates.
- dBA = A-weighted sound power level
- Reference power : 1pW
- Measured according to ISO 3741
• 5)* These products contain R32 (GWP=675) which is fluorinated greenhouse gas.
18
H / Silent
dB(A)
dB(A)
kg
kg
mm
mm
-
AR4500
AR18TXHZAWKNEU
41 / 28
58
11.5
13.7
1,055 x 299 x 215
1,115 x 290 x 375
HIPS
AR4500
AR24TXHZAWKNEU
45 / 29
62
12.5
14.8
1,055 x 299 x 215
1,115 x 290 x 375
HIPS