Samsung AJ040TXJ2KG/EU Technical Data Book page 313

Free joint multi for europe r32, 50hz, hp
Table of Contents

Advertisement

13. Installation
◆ AJ052/068TXJ3KG
1 Piping outside diameter
Indoor unit
AR07/09/12********,
AJ016/020/026
AJ052TXJ3KG
/035TN*D*G
AJ068TXJ3KG
AR18********,
AJ052TN*D*G
NOTE
• AJ052TXJ3KG Outdoor unit cannot be connected to
the following indoor unit combination.
- AJ052TNNDKG/AJ052TNMDEG
• AJ068TXJ3KG Outdoor unit cannot be connected to
the following indoor unit combination.
- AJ***TNJDKG
2 Piping outside diameter
1 Room max
length
Dimension
25m
Composition
A,B,C
※ In case you want more information about the controllers and accessories, please refer to the Controller and Accessory TDB
on pvi.Samsung.com site or Global Partner Portal site.
Outside
Power
diameter
Out unit
supply Ø,
V, Hz
Liquid
1,220-240,
1/4"
50
C
A
B
Main power switch
Max height
3 Room total
Max height
between
max
indoor unit &
length
indoor units
outdoor unit
50m
15m
A+B+C
(H)
Make at least one round:
It will reduce noise and vibration
◆ AJ080TXJ4KG
1 Piping outside diameter
Indoor unit
Gas
AR07/09/12********,
AJ016/020/026
3/8"
/035TN*D*G
AR18********,
AJ052TN*D*G
1/2"
AR24********
(h) (H)
NOTE
• AJ080TXJ4KG Outdoor unit cannot be connected to
the following indoor unit combination.
- AJ***TNJDKG
2 Piping length and the height
Dimension
Composition
between
7.5m
(h)
Power
Out unit
supply Ø, V,
Hz
AJ080TXJ4KG 1,220-240, 50
B
C
A
Main power switch
Max height
1 Room
4 Room
between
max
total max
indoor unit &
length
length
outdoor unit
25m
70m
15m
A,B,C,D
A+B+C+D
(H)
Make at least one round:
It will reduce noise and vibration
Outside
diameter
Liquid
Gas
3/8"
1/4"
1/2"
5/8"
(h) (H)
D
Max height
between
indoor units
7.5m
(h)
313