WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualifi ed electrician.
• To avoid overheating and possible damage to this device and other equipment, do not install to
control a receptacle, fl uorescent lighting, a motor- or a transformer-operated appliance.
• Use with magnetic low-voltage transformers, incandescent, or 120V halogen fi xtures only. Use a Leviton
electronic low-voltage dimmer to control electronic (solid state) low-voltage transformers.
• Total minimum load must exceed 40W or 40VA.
Tools needed to install your Dimmer:
Slotted/Phillips Screwdriver
Electrical Tape
Pliers
Pencil
Cutters
Ruler
Changing the color of your Dimmer:
Your Dimmer includes two color options. The Dimmer ships with the
White frame attached. To change color of frame, proceed as follows:
NOTE: Ensure cut-out for Air-Gap Switch is positioned on bottom.
Push in side at tab
to release
Installing Dimmer by itself or with other devices:
If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER section. If installing Dimmer in a multi-
device application, proceed as follows:
MULTI-DEVICE APPLICATION:
NOTE: You only need to remove side sections if installing with other
dimmers or if it does not fi t in wall box – not when installing with
mechanical switches.
When installing more than one dimmer in the same location, the side
sections of the mounting strap must be removed. Use pliers to carefully
bend side sections back and forth until they break off. The side sections
dissipate heat, so removing them requires a derating of the dimmer's
capacity (refer to chart).
Remove all
inner side
sections
Do not
remove
outer
Bend back and
side
forth to remove
sections
side section
Single Pole (One location) or 3-Way (Multi-location)
Magnetic Low-Voltage Dimmer
For use w/ Cat. No. TTØØR-1 True Touch
INSTALLATION INSTRUCTIONS
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
Cat. No.
TTM1Ø-1
MAXIMUM BULB WATTAGE:
Low-voltage dimmers are rated in Volt-Amps (VA). The maximum bulb
wattage is determined by the effi ciency of the transformer in the low-
voltage lighting system. Transformer effi ciencies will vary from different
manufacturers; consider 75% effi cient as average. Use the chart to
determine maximum bulb wattage for typical transformer effi ciency ratings.
MAXIMUM BULB WATTAGE AT 75% EFFICIENCY
Rating
Cut-out for Air
1000VA
Gap Switch
Line up tabs and
INSTALLING YOUR DIMMER
press in side to attach
NOTE: Use check boxes
WARNING:
Step 1
POWER at circuit breaker or fuse and test that power is off
before wiring!
Removing existing switch:
Step 2
wallplate and switch mounting screws. Carefully pull switch
from wall box. DO NOT remove wires attached to the switch
at this time.
Identifying your wiring application (most common):
Step 3
NOTE: If the wiring in the wall box does not resemble any of
these confi gurations, consult a qualifi ed electrician.
Cat. No. TTM1Ø-1
1000VA-120VAC, 60Hz
TM
Remote in Multi-Location Applications
WARNINGS AND CAUTIONS:
• When a magnetic low-voltage circuit is operated at a dim level, with all lamps inoperative, excess current
may fl ow through the transformer. To avoid possible transformer failure due to overcurrent, use a
transformer that incorporates thermal protection or a fuse at the primary windings.
• Use only one (1) dimmer per load. For remote operation, use Leviton Remote, Cat. No. TTØØR-1.
Do not use a 3-way switch.
• Disconnect power at circuit breaker or fuse when servicing fi xture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked
CO/ALR or CU/AL.
More than
Single
Two Devices
2 Devices
1000VA
800VA
700VA
More than
Single
Two Devices
2 Devices
750W
600W
525W
when Steps are completed.
To avoid fi re, shock, or death; TURN OFF
Remove existing
Step 3
con't
Tag Common Screw Wire
(screw is usually black and/or
marked "common")
Single-Pole:
3-Way:
Look at the back of your switch.
Look at the back of your switch.
If there are 2 wires connected
If there are 3 wires connected
to two screw terminals (not
to three screw terminals (not
including a green or bare copper
including a green or bare copper
wire used for grounding), you
wire used for grounding), you
have a Single-Pole switch.
have a 3-Way switch. DO NOT
add a single-pole switch in this
location.
Disconnecting switch wires and preparing wires:
Step 4
• Disconnect wires from screw terminals or
Quickwire™ slots (shown).
• Pull off pre-cut insulation from Dimmer leads.
• Make sure that the ends of the wires from the
wall box are straight (cut if necessary).
• Remove 5/8" (1.6 cm) of insulation from each
wire in the wall box (shown).
• For Single-Pole Application, go to Step 5a.
• For 3-Way Application, go to Step 5b.
Cut
Press in slot and
(if necessary)
pull out wire
Strip 5/8"
(1.6 cm)
5/8"
(1.6 cm)
Strip Gage

Advertisement

loading

Summary of Contents for Leviton Decora True Touch TTM10-1

  • Page 1 fl ow through the transformer. To avoid possible transformer failure due to overcurrent, use a transformer that incorporates thermal protection or a fuse at the primary windings. • Use only one (1) dimmer per load. For remote operation, use Leviton Remote, Cat. No. TTØØR-1. Do not use a 3-way switch.