SYSTEM CHARGE FOR VARIOUS MATCHED SYSTEMS - A COIL

Outdoor unit
Required indoor metering
1,2
device
3,4,5
Indoor unit
XAF/XAH/XAUA24B
XAF/XAH/XAUB30C
XAF/XAH/XAUB36D
XAF/XAH/XAUC42E
XAF/XAH/XAUC48F
XAF/XAH/XAUC60G
XAF/XAH/XAUD60G
XAF/XAH/XAUD60H
XAF/XAHB24B
XAF/XAHC30C
XAF/XAHC36D
XAF/XAHC60H
XAF/XAHD42E
XAF/XAHD48F
XAF/XAUA24B
XAFA30D
XAFB36E
Note: Some of the combinations shown in this table require advanced main air circulating fan indoor product. For approved coil only matches, refer to
the COOLING CAPACITY - Upflow, Downflow, and Horizontal Furnaces and Coils (Coil Only Ratings) table in the Technical Guide.
1. For applications that require a TXV, use S1-1TVM*** series kit.
2. A TXV kit must be used with these indoor units to obtain system performance.
3. Systems matched with furnaces or air handlers not equipped with blower-off delays may require blower time delay.
4. Do not use XAF/XAU coils in horizontal applications. Do not use XAH coils in upflow/downflow applications.
5. Charge adders shown above do not indicate that coils are rated for every application. Refer to the performance data tables in the Technical Guide for actual performance
for specified system matches. Obtain certified system ratings from
Charging
1. Check the factory unit charge listed on the unit nameplate to verify the refrigerant charge for the outdoor unit, the smallest matched indoor unit,
and the 15 ft of interconnecting refrigeration piping.
2. Verify the indoor metering device and additional charge required for the specific matched indoor unit in the system using the table above.
3. Add additional charge for the amount of interconnecting refrigeration piping greater than 15 ft at the rate specified in the Physical and electrical
data table.
4. For installations requiring additional charge, weigh in refrigerant for the specific matching indoor unit and actual refrigeration piping length.
5. After weighing in the charge adders for the matched indoor unit and refrigeration piping, verify the system operation against the temperatures
and pressures in the charging chart for the outdoor unit. Locate the charging charts on the outdoor unit and also in the Service Data Application
Guide on
www.simplygettingthejobdone.com.
type of indoor metering device in the system, and allow 10 min after each charge adjustment for the system operation to stabilize. Record the
charge adjustment made to match the charging chart.
6. Permanently stamp the unit nameplate with the total system charge defined as follows: total system charge = base charge (as shipped) +
charge adder for matched indoor unit + charge adder for actual refrigeration piping length + charge adjustments to match the charging
chart.
Johnson Controls Ducted Systems
YCE18B22S
YCE24B22S
BA1
BA1
2
3
2
0
3
0
www.ahridirectory.org.
Follow the subcool or superheat charging procedure in the Installation Manual according to the
YCE30B22S
YCE36B22S
BA1
BC1
Additional charge (oz)
0
6
0
2
0
6
0
2
-
6
2
5581700-YTG-F-1021
YCE42B22S
YCE48B21S
BC1
BC1
0
2
0
5
5
0
2
0
YCE60B21S
BC1
0
0
6
6
5