Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73°F to 87°F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COIL MULTIPLIERS - 1.5 TON
Air Handler
Coil
—
CF/CM/CU18A
—
CF/CM/CU18B
—
CF/CM/CU24A
—
CF/CM/CU24B
—
CF/CM/CU30A
—
CF/CM/CU30B
—
CF/CM/CU36B
—
CF/CM/CU36C
—
CF/CM24C
—
CF/CM30C
—
CF/CM36D
—
XAF/XAUA24B
—
XAFB24B
—
XAHA24B
—
XAHB24B
AE18BX21
AE24BX21
AE30BX21
AE36CX21
AP18BX21
AP24BX21
AVC18BX21
AVC24BX21
AVC30BX21
ME08BN21
CF/CM18B
ME08BN21
CF/CM24B
ME08BN21
CF/CM30B
ME08BN21
CF/CM36B
ME12BN21
CF/CM18B
ME12BN21
CF/CM24B
ME12BN21
CF/CM30B
ME12BN21
CF/CM36B
ME12CN21
CF/CM24C
ME12CN21
CF/CM30C
ME12CN21
CF/CM36C
MVC08BN21
CF/CM18B
MVC08BN21
CF/CM24B
MVC08BN21
CF/CM30B
MVC08BN21
CF/CM36B
MVC12CN21
CF/CM24C
MVC12CN21
CF/CM30C
MVC12CN21
CF/CM36C
Johnson Controls Ducted Systems
T.C.
S.C.
1.00
1.00
1.00
1.12
1.02
1.09
1.02
1.09
1.04
1.07
1.04
1.07
1.04
1.05
1.04
1.05
1.02
1.09
1.04
1.07
1.04
1.05
1.02
1.07
1.02
1.07
1.02
1.07
1.02
1.07
—
1.05
1.09
—
1.05
1.07
—
1.05
1.05
—
1.05
1.06
—
1.03
1.12
—
1.04
1.14
—
1.05
1.09
—
1.05
1.07
—
1.05
1.09
1.04
1.07
1.04
1.06
1.05
1.05
1.05
1.02
1.05
1.11
1.05
1.12
1.05
1.09
1.05
1.09
1.05
1.06
1.05
1.05
1.05
1.04
1.05
1.09
1.05
1.10
1.05
1.07
1.05
1.07
1.05
1.10
1.05
1.08
1.05
1.06
FURNACE MULTIPLIERS - 1.5 TON
kW
Furnaces
1.00
TL8E060A12UH11
1.00
TL8E060A12UH11
1.02
TL8E060A12UH11
1.02
TL8E060A12UH11
1.01
TL8E060A12UH11
1.01
TL8E060A12UH11
1.02
TL8E060A12UH11
1.02
TL8E060A12UH11
1.02
TL8E060A12UH11
1.01
TL8E060A12UH11
1.02
TL8E060A12UH11
1.02
TL8E060A12UH11
1.02
TL9E060B12UH11
1.02
TL9E060B12UH11
1.02
TL9E060B12UH11
0.95
TL9E060B12UH11
0.95
TL9E060B12UH11
0.95
TL9E060B12UH11
0.95
TL9E060B12UH11
1.01
TL9E060B12UH11
1.01
TL9E060B12UH11
0.95
TM8E040A12MP11
0.95
TM8E040A12MP11
0.95
TM8E040A12MP11
0.94
TM8E040A12MP11
0.94
TM8E040A12MP11
0.95
TM8E040A12MP11
0.95
TM8E040A12MP11
0.95
TM8E040A12MP11
0.95
TM8E040A12MP11
0.95
TM8E040A12MP11
0.95
TM8E040A12MP11
0.95
TM8E040A12MP11
0.95
TM8E060A12MP11
0.95
TM8E060A12MP11
0.95
TM8E060A12MP11
0.95
TM8E060A12MP11
0.95
TM8E080B12MP11
0.95
TM8E080B12MP11
0.95
TM8E080B12MP11
0.95
TM8E080B12MP11
0.95
TM8E080B12MP11
TM8E100B12MP11
TM8E100B12MP11
TM8E100B12MP11
TM8E100B12MP11
TM8E100B12MP11
TM8E100B12MP11
TM8E100B12MP11
TM8E100B12MP11
TM8V060A12MP11C
TM8V060A12MP11C
5581700-YTG-F-1021
T.C.
S.C.
Coil
CF/CM/CU18A
1.04
1.16
CF/CM/CU18B
1.04
1.19
CF/CM/CU24A
1.04
1.15
CF/CM/CU24B
1.04
1.25
CF/CM/CU30A
1.04
1.15
CF/CM/CU30B
1.05
1.23
CF/CM/CU36B
1.05
1.22
CF/CM36A
1.05
1.20
XAF/XAUA24B
1.04
1.07
XAFB24B
1.04
1.13
XAHA24B
1.04
1.07
XAHB24B
1.04
1.09
CF/CM/CU18B
1.03
1.19
CF/CM/CU24B
1.04
1.20
CF/CM/CU30B
1.05
1.20
CF/CM/CU36B
1.05
1.19
CF/CM/CU36C
1.05
1.22
CF/CM24C
1.04
1.20
CF/CM30C
1.05
1.23
XAFB24B
1.04
1.09
XAHB24B
1.04
1.09
CF/CM/CU18A
1.04
1.19
CF/CM/CU18B
1.04
1.21
CF/CM/CU24A
1.04
1.20
CF/CM/CU24B
1.04
1.24
CF/CM/CU30A
1.04
1.17
CF/CM/CU30B
1.04
1.20
CF/CM/CU36B
1.05
1.22
CF/CM36A
1.05
1.25
XAF/XAUA24B
1.04
1.09
XAFB24B
1.04
1.13
XAHA24B
1.04
1.09
XAHB24B
1.04
1.11
CF/CM/CU30A
1.04
1.24
CF/CM36A
1.05
1.25
XAF/XAUA24B
1.05
1.17
XAHA24B
1.05
1.17
CF/CM/CU30B
1.04
1.24
CF/CM/CU36B
1.05
1.25
CF/CM24B
1.05
1.11
XAFB24B
1.05
1.17
XAHB24B
1.05
1.15
CF/CM/CU18B
1.03
1.24
CF/CM/CU30B
1.04
1.24
CF/CM/CU36B
1.05
1.25
CF/CM/CU36C
1.05
1.24
CF/CM24B
1.05
1.11
CF/CM30C
1.04
1.24
XAFB24B
1.05
1.15
XAHB24B
1.05
1.15
CF/CM/CU18A
1.05
1.18
CF/CM/CU18B
1.05
1.18
kW
0.96
0.94
0.94
0.94
0.94
0.95
0.95
0.95
0.96
0.96
0.96
0.96
0.95
0.94
0.95
0.95
0.95
0.94
0.95
0.96
0.96
0.94
0.96
0.94
0.94
0.94
0.94
0.95
0.95
0.96
0.96
0.96
0.96
0.94
0.95
0.92
0.92
0.94
0.95
0.92
0.92
0.92
0.93
0.94
0.95
0.95
0.91
0.94
0.91
0.91
0.95
0.95