York LX Series Technical Manual page 80

Split system air conditioners 14 seer - r-410a - 1 phase 1.5 to 5 nominal ton
Hide thumbs Also See for LX Series:
Table of Contents

Advertisement

5581700-YTG-F-1021
SYSTEM CAPACITY - With High Efficiency Motor Furnaces
UNIT
MODEL
YCE42B22S
TM8E120C20MP11
YCE42B22S
TM8E120C20MP11
YCE42B22S
TM8E120C20MP11
YCE42B22S
TM8E120C20MP11
YCE42B22S
TM8E120C20MP11
YCE42B22S
TM8E120C20MP11
YCE42B22S
TM8E120C20MP11
YCE42B22S
TM8E120C20MP11
YCE42B22S
TM8E120C20MP11
YCE42B22S
TM8E130D20MP11
YCE42B22S
TM8E130D20MP11
YCE42B22S
TM8E130D20MP11
YCE42B22S
TM8E130D20MP11
YCE42B22S
TM8E130D20MP11
YCE42B22S
TM8E130D20MP11
YCE42B22S
TM8E130D20MP11
YCE42B22S
TM8V060A12MP11C
YCE42B22S
TM8V060A12MP12C
YCE42B22S
TM8V080C16MP11C
YCE42B22S
TM8V080C16MP11C
YCE42B22S
TM8V080C16MP11C
YCE42B22S
TM8V080C16MP11C
YCE42B22S
TM8V080C16MP11C
YCE42B22S
TM8V080C16MP11C
YCE42B22S
TM8V080C16MP11C
YCE42B22S
TM8V080C16MP12C
YCE42B22S
TM8V080C16MP12C
YCE42B22S
TM8V080C16MP12C
YCE42B22S
TM8V080C16MP12C
YCE42B22S
TM8V080C16MP12C
YCE42B22S
TM8V080C16MP12C
YCE42B22S
TM8V080C16MP12C
YCE42B22S
TM8V080C16MP12C
YCE42B22S
TM8V080C16MP12C
YCE42B22S
TM8V080C16MP12C
YCE42B22S
TM8V080C16MP12C
YCE42B22S
TM8V080C16MP12C
YCE42B22S
TM8V080C16MP12C
YCE42B22S
TM8V080C16MP12C
YCE42B22S
TM8V080C16MP12C
YCE42B22S
TM8V100C16MP11C
YCE42B22S
TM8V100C16MP11C
YCE42B22S
TM8V100C16MP11C
YCE42B22S
TM8V100C16MP11C
YCE42B22S
TM8V100C16MP11C
YCE42B22S
TM8V100C16MP11C
YCE42B22S
TM8V100C16MP11C
YCE42B22S
TM8V100C16MP12C
YCE42B22S
TM8V100C16MP12C
YCE42B22S
TM8V100C16MP12C
YCE42B22S
TM8V100C16MP12C
YCE42B22S
TM8V100C16MP12C
YCE42B22S
TM8V100C16MP12C
80
FURNACE
MODEL
WIDTH
21.0
21.0
21.0
24.5
24.5
21.0
21.0
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
14.5
14.5
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
24.5
24.5
21.0
21.0
24.5
24.5
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
1
(Continued)
COIL
RATED
2
MODEL
CFM
CF/CM42D
1300
XAF/XAUC42E
1250
XAF/XAUC48F
1250
XAFD42E
1250
XAFD48F
1275
XAHC42E
1225
XAHC48F
1275
XAHD42E
1225
XAHD48F
1275
CF/CM/CU48D
1300
CF/CM/CU60D
1325
CF/CM42D
1300
XAFD42E
1250
XAFD48F
1275
XAHD42E
1225
XAHD48F
1250
CF42B
1275
CF42B
1275
CF/CM/CU42C
1200
CF/CM/CU48C
1200
CF/CM/CU48D
1200
CF/CM/CU60C
1200
CF/CM/CU60D
1200
CF/CM42D
1200
CF/CM64D
1200
CF/CM/CU42C
1200
CF/CM/CU48C
1200
CF/CM/CU48D
1200
CF/CM/CU60C
1200
CF/CM/CU60D
1200
CF/CM42D
1200
CF/CM64D
1200
XAF/XAUC42E
1200
XAF/XAUC48F
1200
XAFD42E
1200
XAFD48F
1200
XAHC42E
1200
XAHC48F
1200
XAHD42E
1200
XAHD48F
1200
CF/CM/CU42C
1200
CF/CM/CU48C
1200
CF/CM/CU48D
1200
CF/CM/CU60C
1200
CF/CM/CU60D
1200
CF/CM42D
1200
CF/CM64D
1200
CF/CM/CU42C
1200
CF/CM/CU48C
1200
CF/CM/CU48D
1200
CF/CM/CU60C
1200
CF/CM/CU60D
1200
CF/CM42D
1200
COOLING
NET MBH
SEER
TOTAL
SENS.
42.0
31.6
15.00
41.5
28.4
15.00
41.5
28.0
15.00
41.5
28.8
15.00
41.0
28.2
15.00
41.5
28.2
14.75
41.5
28.2
15.00
41.0
28.2
14.75
41.0
28.2
15.00
42.0
32.2
15.25
42.0
31.8
15.25
42.0
31.8
15.25
42.0
28.8
15.00
41.5
28.2
15.00
41.5
28.2
14.75
41.5
28.0
15.00
40.5
30.6
14.00
40.5
30.6
14.00
41.0
30.2
14.75
41.5
31.0
15.00
41.5
31.0
15.00
41.5
30.4
14.75
41.5
30.8
15.00
41.0
30.4
15.00
42.0
30.8
15.25
41.0
30.2
14.75
41.5
31.0
15.00
41.5
31.0
15.00
41.5
30.4
14.75
41.5
30.8
15.00
41.0
30.4
15.00
42.0
30.8
15.25
41.5
28.2
14.50
41.0
27.6
14.50
41.0
28.2
14.75
40.5
27.4
14.50
41.0
27.8
14.50
41.0
27.4
14.75
41.0
28.2
14.50
40.5
27.6
14.50
41.0
30.2
14.75
41.5
31.0
15.00
41.5
31.0
15.00
41.5
30.4
14.75
41.5
30.8
15.00
41.0
30.4
15.00
42.0
30.8
15.25
41.0
30.2
14.75
41.5
31.0
15.00
41.5
31.0
15.00
41.5
30.4
14.75
41.5
30.8
15.00
41.0
30.4
15.00
Johnson Controls Ducted Systems
EER
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.50
12.00
12.00
12.50
12.50
12.50
12.50
12.50
12.50
12.75
12.50
12.50
12.50
12.50
12.50
12.50
12.75
12.25
12.25
12.50
12.50
12.25
12.50
12.25
12.25
12.50
12.50
12.50
12.50
12.50
12.50
12.75
12.50
12.50
12.50
12.50
12.50
12.50

Advertisement